SECTION 2
22
BLUE
LINE VORTEX 8000Q
B.
If the nozzles are not showing a full
even spray pattern, adjust, clean, or
replace the nozzles, if required.
2. Usually, chemical solution is applied during
the push stroke of the wand during cleaning,
and extraction is done on the pull stroke. For
heavily soiled carpets, the wand may be used
in a scrubbing action, with chemical solution
applied in both push and pull strokes,
provided that the final stroke is a pull stroke
with no chemical injection.
UPHOLSTERY CLEANING
1. Upholstery tools have a lower flow rate and
smaller orifices. Set the
temperature control
to the desired setting. To maintain proper
cleaning temperatures, make certain that the
unit has been fully heated up prior to cleaning.
2. Always clean upholstery with a pressure
setting below 300 PSI, by adjusting the
pressure regulator on the unit.
STAIR TOOL CLEANING
1. Set the
temperature control
to the desired
setting. To maintain proper cleaning
temperatures, make certain that the unit has
been fully heated up prior to cleaning.
FLOOD
RESTORATION/EXTRACTION
1. Depress the
RPM INCREASE
switch until
the engine speed reaches 1700 RPM. Make
certain that the
ENGAGE PUMP
switch
is in
the
OFF
position. Proceed into the extraction
process.
SHUT DOWN AND DAILY
MAINTENANCE
1. Flush out the chemical system with fresh
water to remove any chemical residue.
2. Remove as much moisture from the vacuum
hoses as possible. This will prevent spillage of
wastewater in your vehicle when returning
hoses.
3. Disconnect the vacuum hoses from the pre-
filter box inlets.
4. Depress the
RPM DECREASE
switch
until the engine speed returns to idle.
5. Turn the temperature control down to 150
deg. F.
6. Allow the unit to run for at least
2 minutes
or until the water temperature is at or below
180 deg. F. This will also help to remove any
excess moisture from the vacuum pump.
NOTE:
If shutting down for the day: Plug the
vacuum inlets on the inlet panel and pull out
the
ENGAGE PUM
P switch on the control
panel. Spray WD-40 (or equivalent) into the
blower lubrication reservoir
until the
reservoir is approximately half full. Open the
blower
lubrication valve
located on the front
left of the vacuum hose reel. This will
lubricate the vacuum pump. Next, disengage
the
PUMP
switch
,
and continue with step 4.
Содержание VORTEX 8000Q
Страница 5: ......
Страница 14: ...SECTION 2 BLUELINE VORTEX 8000Q 9 ...
Страница 17: ...SECTION 2 12 BLUELINE VORTEX 8000Q Water System 2 1 ...
Страница 21: ...SECTION 2 16 BLUELINE VORTEX 8000Q ...
Страница 33: ...SECTION 3 28 BLUELINE VORTEX 8000Q Figure 1 Figure 2 Mark Mark ...
Страница 75: ...SECTION 4 70 BLUELINE VORTEX 8000Q ...
Страница 82: ...SECTION 4 76 BLUELINE VORTEX 8000Q 68 102 KIT VORTEX STORAGE RACKS 68 013 ASSY VAN STORAGE UNIT SS ...
Страница 83: ...SECTION 4 BLUELINE VORTEX 8000Q 77 68 014 ASSY SINGLE 5 GAL JUG HOLDER 68 015 ASSY FURN BLOCK HOLDER SS ...
Страница 84: ...SECTION 4 78 BLUELINE VORTEX 8000Q 68 016 RACK DOUBLE CHEMICAL 68 018 ASSY 10 GAL CHEM RACK S S ...
Страница 85: ...SECTION 4 BLUELINE VORTEX 8000Q 79 68 019 SPRAY BOTTLE HOLDER SS 68 022 ASSY DBL PMP UP SPRAY RK SS ...
Страница 86: ...SECTION 4 80 BLUELINE VORTEX 8000Q 68 024 ASSY SNG PMP UP SPRAY RK SS 68 023 ASSY REEL HP SOLUTION ...
Страница 87: ...SECTION 4 BLUELINE VORTEX 8000Q 81 68 025 ASSY HOSE REEL HIGH PROFILE 68 033 ASSY HOSE REEL H PROFILE W MTR ...
Страница 88: ...SECTION 4 82 BLUELINE VORTEX 8000Q 68 037 ASSY HOSE REEL VAC ONLY 68 045 ASSY WATER SOFTENER ...
Страница 89: ...SECTION 4 BLUELINE VORTEX 8000Q 83 68 109 ASSY KIT WATER SOFTENER VRTX ...
Страница 90: ...84 BLUELINE VORTEX 8000Q SECTION 5 SERVICE BULLETINS 11 SERVICE BULLETINS ...