SECTION 2
BLUE
LINE VORTEX 8000Q
17
ENSURE THERE IS ADEQUATE FUEL
Check the fuel tank to ensure there is adequate
fuel to complete the job and transport the
vehicle. This unit consumes approximately 2
gallons of diesel fuel per hour, when operating
the engine in the proper RPM range.
CHECK WATER PUMP OIL LEVEL
Check the water pump oil
daily
prior to
starting the mobile cleaning unit. With the
truck on a level surface check the sight gauge
on the water pump. Oil level should be in the
center of the gauge. If the oil is below the
center red dot, add oil and check for leaks.
DO NOT overfill or damage may occur to
the pump.
(CAT Pump Crankcase Oil, Part # 13-000)
Water Pump Oil Level
CHECK HEAT TRANSFER OIL LEVEL
With the mobile cleaning unit parked on level
ground with the unit off, and the heat
exchanger temperature between 60° to 90° F.
NOTE:
(
Failure to follow the preceding will
result in an inaccurate reading.)
Check the
oil level on the upper xentherm heat
exchanger sight glass. Normal oil level should
be 1/2 to 3/4 of the sight glass. Add heat
transfer oil as needed.
Do not overfill.
NOTE: This is a closed loop system, any
loss of fluid indicates a problem within the
system, and must be repaired prior to any
further use.
Do not overfill heat transfer fluid. The heat
transfer fluid will expand as it heats up.
Failure to follow these procedures could
result in injury and or fatality and damage
to property.
Upper Xentherm Fluid Level
PRE-FILTER BOX AND WASTE TANK
Clean or replace strainer basket located in the
pre-filter box. Inspect and clean or replace
filters located inside the waste recovery tank.
This will help to prevent damage to the
system vacuum pump.
NOTE:
To remove the vacuum inlet filters,
grip the plastic hexagon section of the filters.
Gripping the filters by the screen will collapse
or destroy the filters. Replace the filters after
cleaning until hand tight.
TRUCK ENGINE OIL/RADIATOR
Check the engine oil and anti-freeze levels.
Refer to vehicle owner’s manual for
recommended fluid levels and maintenance
schedule.
FRESH WATER TANK
Connect the water supply hose to the water
inlet quick connector on the top of the fresh
water tank. Connect the hose to the faucet.
Turn the water supply faucet on. Fill the tank
Содержание VORTEX 8000Q
Страница 5: ......
Страница 14: ...SECTION 2 BLUELINE VORTEX 8000Q 9 ...
Страница 17: ...SECTION 2 12 BLUELINE VORTEX 8000Q Water System 2 1 ...
Страница 21: ...SECTION 2 16 BLUELINE VORTEX 8000Q ...
Страница 33: ...SECTION 3 28 BLUELINE VORTEX 8000Q Figure 1 Figure 2 Mark Mark ...
Страница 75: ...SECTION 4 70 BLUELINE VORTEX 8000Q ...
Страница 82: ...SECTION 4 76 BLUELINE VORTEX 8000Q 68 102 KIT VORTEX STORAGE RACKS 68 013 ASSY VAN STORAGE UNIT SS ...
Страница 83: ...SECTION 4 BLUELINE VORTEX 8000Q 77 68 014 ASSY SINGLE 5 GAL JUG HOLDER 68 015 ASSY FURN BLOCK HOLDER SS ...
Страница 84: ...SECTION 4 78 BLUELINE VORTEX 8000Q 68 016 RACK DOUBLE CHEMICAL 68 018 ASSY 10 GAL CHEM RACK S S ...
Страница 85: ...SECTION 4 BLUELINE VORTEX 8000Q 79 68 019 SPRAY BOTTLE HOLDER SS 68 022 ASSY DBL PMP UP SPRAY RK SS ...
Страница 86: ...SECTION 4 80 BLUELINE VORTEX 8000Q 68 024 ASSY SNG PMP UP SPRAY RK SS 68 023 ASSY REEL HP SOLUTION ...
Страница 87: ...SECTION 4 BLUELINE VORTEX 8000Q 81 68 025 ASSY HOSE REEL HIGH PROFILE 68 033 ASSY HOSE REEL H PROFILE W MTR ...
Страница 88: ...SECTION 4 82 BLUELINE VORTEX 8000Q 68 037 ASSY HOSE REEL VAC ONLY 68 045 ASSY WATER SOFTENER ...
Страница 89: ...SECTION 4 BLUELINE VORTEX 8000Q 83 68 109 ASSY KIT WATER SOFTENER VRTX ...
Страница 90: ...84 BLUELINE VORTEX 8000Q SECTION 5 SERVICE BULLETINS 11 SERVICE BULLETINS ...