SECTION 2
BLUE
LINE VORTEX 8000Q
19
JET SIZING
BLUE
LINE recommends that the total floor
tool size does not exceed “.12”. Using larger
jet sizes on your
VORTEX mobile cleaning
unit
may reduce cleaning temperatures.
Example:
Four–jet wand uses four 95015 jets.
(95 deg. Spray angle w/015 orifice)
.
015 x 4 = .06
When using two wands while cleaning with
this unit,
BLUE
LINE recommends that the tip
size in each tool does not exceed a total of
“.18”.
Example:
Four jet wand uses four 9501 jets.
(95 deg. Spray angle w/01 orifice)
.01 x 4 = .04 x 2 tools = .08
Upholstery tool jet size: 80015.
Stair tool jet size: 9502
STARTING THE UNIT
!
Operate this unit and equipment only in a
well ventilated area. Exhaust fumes contain
carbon monoxide, which is an odorless and
deadly poison that can cause severe injury
or death. DO NOT run this unit in an
enclosed area. DO NOT operate this unit
where the exhaust may enter a building
doorway, window, vent or any other
opening.
1. With the truck running at idle
(approximately 700 RPM) pull the main
power switch to energize the control panel.
2. Push the
―ENGAGE PT
O‖
switch. in, to
engage the PTO. The blower pulley will start
turning. Allow approximately 30 seconds for
the mobile cleaning unit to stabilize at idle
speed.
NOTE: Engage PTO with engine at idle
speed.
3. Set the oil temperature gauge to the desired
cleaning temperature. Press and hold the high
temperature control button, located on the
lower right of the temperature gauge.
Temperature will change rapidly. To set
temperature at 1° increments, press and
release button until desired temperature is
reached.
NOTE: The upper limit of oil
temperature is 320°F.
Repeat this operation to lower the oil
temperature using the button located on the
lower left of the temperature gauge.
NOTE:
The lower limit of the oil temperature is
150°F.
The lower digital display on the gauge
shows the oil set temperature. The upper
digital display is the actual oil temperature.
There is a 5 second delay after releasing either
high or low temperature set button, before the
set point is stored. System will function
normally after the set point is stored.
The thermostatic control is designed to
maintain the solution temperature
automatically.
4. To engage the water and oil pump, pull out
the
―ENGAGE PUMP
‖
switch. Allow
approximately 30 seconds for the engine to
Содержание VORTEX 8000Q
Страница 5: ......
Страница 14: ...SECTION 2 BLUELINE VORTEX 8000Q 9 ...
Страница 17: ...SECTION 2 12 BLUELINE VORTEX 8000Q Water System 2 1 ...
Страница 21: ...SECTION 2 16 BLUELINE VORTEX 8000Q ...
Страница 33: ...SECTION 3 28 BLUELINE VORTEX 8000Q Figure 1 Figure 2 Mark Mark ...
Страница 75: ...SECTION 4 70 BLUELINE VORTEX 8000Q ...
Страница 82: ...SECTION 4 76 BLUELINE VORTEX 8000Q 68 102 KIT VORTEX STORAGE RACKS 68 013 ASSY VAN STORAGE UNIT SS ...
Страница 83: ...SECTION 4 BLUELINE VORTEX 8000Q 77 68 014 ASSY SINGLE 5 GAL JUG HOLDER 68 015 ASSY FURN BLOCK HOLDER SS ...
Страница 84: ...SECTION 4 78 BLUELINE VORTEX 8000Q 68 016 RACK DOUBLE CHEMICAL 68 018 ASSY 10 GAL CHEM RACK S S ...
Страница 85: ...SECTION 4 BLUELINE VORTEX 8000Q 79 68 019 SPRAY BOTTLE HOLDER SS 68 022 ASSY DBL PMP UP SPRAY RK SS ...
Страница 86: ...SECTION 4 80 BLUELINE VORTEX 8000Q 68 024 ASSY SNG PMP UP SPRAY RK SS 68 023 ASSY REEL HP SOLUTION ...
Страница 87: ...SECTION 4 BLUELINE VORTEX 8000Q 81 68 025 ASSY HOSE REEL HIGH PROFILE 68 033 ASSY HOSE REEL H PROFILE W MTR ...
Страница 88: ...SECTION 4 82 BLUELINE VORTEX 8000Q 68 037 ASSY HOSE REEL VAC ONLY 68 045 ASSY WATER SOFTENER ...
Страница 89: ...SECTION 4 BLUELINE VORTEX 8000Q 83 68 109 ASSY KIT WATER SOFTENER VRTX ...
Страница 90: ...84 BLUELINE VORTEX 8000Q SECTION 5 SERVICE BULLETINS 11 SERVICE BULLETINS ...