3. SYSTEMS
NOTE: Read and understand this section of the
manual entirely before proceeding.
This portion of the manual divides the unit up into
systems and describes how each system works.
Prior to proceeding into the operations and
maintenance sections of this manual it is
recommended that you acquire a basic
understanding of how the unit functions.
WATER PUMPING SYSTEM
See figure 2-1. Water flows from the fresh water
tank, through a wye strainer to the water pump
where it is pressurized. The pressurized water is
pumped to the pressure regulator, which maintains
the desired pressure setting. The pump discharge
manifold is equipped with a nitrogen charged
accumulator, which helps reduce pressure
fluctuations.
Water flows from the pressure regulator through
the engine coolant heat exchanger, through the
vacuum exhaust heat exchanger and then through
the upper xentherm heat exchanger.
Water then flows through the metering valve
located on the control panel. At this point, the
chemical injection takes place.
The hot solution mixture of water and chemicals
then flows to the cleaning tool.
HEAT TRANSFER SYSTEM
See figure 2-1 Water is heated through a multi-
stage heat exchange system that utilizes engine
coolant, vacuum exhaust and engine exhaust. Stage
one utilizes hot engine coolant, where the
temperature is maintained at or near 195°F by the
engine thermostat. The engine coolant flows
through the engine heat exchanger heating the
pressurized water supplied by the water pump.
Water then flows through the vacuum exhaust heat
exchanger and into the upper xentherm heat
exchanger. Where oil heated by the engine exhaust
in the lower xentherm heat exchanger is circulated
in a closed loop system, heating the water to the
desired temperature, set with the oil temperature
control located on the control panel.
This unit is equipped with an automatic diverter
valve system located behind the engine muffler.
This system incorporates an electronic rotary
solenoid with an exhaust diverter valve. When the
water temperature reaches the desired setting, the
solenoid automatically positions the diverter valve
into the direct exhaust mode.
The low water level switch located on the water
tank will automatically shut off the water pump
clutch, disengaging the water pump when the fresh
water supply is low. A water tank empty indicator
light, located on the control panel, will then be
illuminated.
Содержание VORTEX 8000Q
Страница 5: ......
Страница 14: ...SECTION 2 BLUELINE VORTEX 8000Q 9 ...
Страница 17: ...SECTION 2 12 BLUELINE VORTEX 8000Q Water System 2 1 ...
Страница 21: ...SECTION 2 16 BLUELINE VORTEX 8000Q ...
Страница 33: ...SECTION 3 28 BLUELINE VORTEX 8000Q Figure 1 Figure 2 Mark Mark ...
Страница 75: ...SECTION 4 70 BLUELINE VORTEX 8000Q ...
Страница 82: ...SECTION 4 76 BLUELINE VORTEX 8000Q 68 102 KIT VORTEX STORAGE RACKS 68 013 ASSY VAN STORAGE UNIT SS ...
Страница 83: ...SECTION 4 BLUELINE VORTEX 8000Q 77 68 014 ASSY SINGLE 5 GAL JUG HOLDER 68 015 ASSY FURN BLOCK HOLDER SS ...
Страница 84: ...SECTION 4 78 BLUELINE VORTEX 8000Q 68 016 RACK DOUBLE CHEMICAL 68 018 ASSY 10 GAL CHEM RACK S S ...
Страница 85: ...SECTION 4 BLUELINE VORTEX 8000Q 79 68 019 SPRAY BOTTLE HOLDER SS 68 022 ASSY DBL PMP UP SPRAY RK SS ...
Страница 86: ...SECTION 4 80 BLUELINE VORTEX 8000Q 68 024 ASSY SNG PMP UP SPRAY RK SS 68 023 ASSY REEL HP SOLUTION ...
Страница 87: ...SECTION 4 BLUELINE VORTEX 8000Q 81 68 025 ASSY HOSE REEL HIGH PROFILE 68 033 ASSY HOSE REEL H PROFILE W MTR ...
Страница 88: ...SECTION 4 82 BLUELINE VORTEX 8000Q 68 037 ASSY HOSE REEL VAC ONLY 68 045 ASSY WATER SOFTENER ...
Страница 89: ...SECTION 4 BLUELINE VORTEX 8000Q 83 68 109 ASSY KIT WATER SOFTENER VRTX ...
Страница 90: ...84 BLUELINE VORTEX 8000Q SECTION 5 SERVICE BULLETINS 11 SERVICE BULLETINS ...