background image

Page 10

3.0  

How To Operate Flex-Pro

Flex-Pro

 M Series, Control Panel - Button Operation

Flex-Pro

Press and release

 to select a Run 

Mode.

Press and hold

 to enter the 

configuration menu for the currently 
active run mode only.

Press and release

 to prime the pump.

Press and release

 to change the roller 

rotation.

Press and release

 to enter the 

configuration menus.

Press and release

 to confirm a 

menu selection.

Press and release

 to view and 

delete revolution counter data.

Press and release

 to select menu 

items, increase menu values by one, 
and increase pump output in 

Manual 

Speed Adjust 

mode.

Press and hold

 to increase values 

progressively faster.

Press and release

 to stop the pump.

Press and release

 to select menu 

items. 

Press and release

 (when not in the 

configuration menu) to toggle the 
display units of measure and to 
display the current input signal 
values

Press and release

 to start the pump.

Press and release

 to select menu 

items, decrease menu values by one, 
and decrease pump output in 

Manual 

Speed Adjust 

mode.

Press and hold

 to decrease values 

progressively faster.

Page 11

Flex-Pro

3.1   Menu Navigation

Use MENU button to enter menu for setting up pump.

Use UP or DOWN arrows to navigate through menu.

Active option appears on pump display in 

 text.

inverse

Plus symbol  

+

  signifies top of a menu tree. This means you can go further 

within the menu.

Within the Menu of the pump, each screen you enter will have a title located 
along the top. This will display the menu that is currently active, or this will be 
the setting you are configuring.

To back out of menu, select 

<- Esc

 line located at end of the list. Then press 

ENTER button. This will take you back one level.

When the menu list extends above or below height of display, a scroll bar will 
appear on left side. Press DOWN arrow to scroll down to the end of the list to 
see a list of all the available options.
Scroll bar example:

While making a selection where only one choice is allowed, you will see a radio 
button.
Radio button example:

In a screen where you are making changes, you will see the word 

Done

 

located at the bottom of the list. You must select 

Done 

in order to leave the 

screen (whether you made a change or not). Selecting 

Done

 will take you back 

to the parent level.

When inputting a numerical value, use UP or DOWN arrow to scroll through 0 - 
9. To move over to the next digit use RIGHT arrow. If you pass your desired 
digit, you can continuously press RIGHT arrow until you reach your desired 
digit.
Numeric value example:

   Solid black means item is selected

   Outline with no fill means item is not selected

000

0

– Sample screen shots –

- Configuration

+ Display Language

<- Esc

+ Reset to Factory Defaults

+ Set Password

+ Display Rate

- Display Rate

   Oz/min
   Liter/Hr
   Gal/Hr (US)
   Gal/day (US)

   Done

- Display Rate

   %Speed
   RPM
   ML/min

   Liter/Hr

   Oz/min

- Menu

+ Configuration

+ Input Setup
+ Output Setup

<- Esc

+ Power Fail option

TUBE

INFO

TUBE

INFO

MODE

M-3

 PERISTALTIC
METERING PUMP

TUBE

INFO

Press

and hold

for Setup

Peristaltic Metering Pump

ProSeries

by Blue-White Ind.

TUBE

INFO

TUBE

INFO

MODE

M-3

 PERISTALTIC
METERING PUMP

TUBE

INFO

Peristaltic Metering Pump

ProSeries

by Blue-White Ind.

Содержание FLEX-PRO PROSERIES-M Flex-A-Chem M-3

Страница 1: ...e White com PROSERIES M M 3 and M 4 Operating and Maintenance Manual ProSeries by Blue White Ind TM FLEX PRO Peristaltic Metering Pump system TFD Tube Failure Detection Exclusive 5 FIVE YEAR WARRANTY...

Страница 2: ...onal Dosing 24 4 4 Contact Closure Input Remote start stop 25 4 5 Set FVS Flow Verification System 26 4 6 TFD Tube Failure Detection 27 4 6 1 TFD Adjustment 27 4 7 Remote Local Control 28 4 8 Set Revo...

Страница 3: ...2100 2100 RPM 125 125 125 PSI bar 65 65 65 4 5 4 5 4 5 65 4 5 PSI bar 125 8 6 125 8 6 125 8 6 PSI bar 50 3 4 50 3 4 F C 185 85 185 85 185 85 F C 130 54 130 54 F C 130 54 130 54 130 54 130 54 Flex A P...

Страница 4: ...e assembly maximum temperature ratings Ambient Operating Temperature O O O O 14 F to 115 F 10 C to 46 C Ambient Storage Temperature O O O O 40 F to 158 F 40 C to 70 C Operating Voltage M 3 MODELS 115V...

Страница 5: ...ustment No maintenance brushless variable speed motor Specially engineered tubing for long life at high pressures Patented Tube Failure Detection TFD system Senses tube failure by detecting chemical i...

Страница 6: ...valves should NOT be used as back flow preven tion valves unless adjusted to the minimum possible opening pressure Any additional pressure at the pump will reduce the life of the pump tube A pressure...

Страница 7: ...easy pump access in hard to reach areas Extended Brackets A B C D E 10 3 4 8 1 8 15 1 4 10 12 1 4 27 3 20 6 38 9 25 4 31 0 14 1 4 12 1 8 18 5 8 11 13 5 8 36 1 30 8 47 3 27 9 34 6 F 4 1 4 10 7 6 15 2...

Страница 8: ...nstalled and sealed Never strap control input output cables and power cables together Power Interruption This pump has a user programmable auto restart feature which will can either restore the pump t...

Страница 9: ...Form C 1 AMP MAX AT 125 VOLT AC 0 8 AMP MAX AT 30 VOLT DC 5A SLOW BLOW 20 X 5MM 1 2 3 T1 PULSE GND 4 20 1 2 3 T1 PULSE GND 4 20 0 10 15VDC 1 2 T2 0 1000 HZ MAX NEGATIVE POSITIVE POSITIVE NEGATIVE NO...

Страница 10: ...l Speed Adjust mode Press and hold to increase values progressively faster Press and release to stop the pump Press and release to select menu items Press and release when not in the configuration men...

Страница 11: ...s Scroll bar example While making a selection where only one choice is allowed you will see a radio button Radio button example In a screen where you are making changes you will see the word Done loca...

Страница 12: ...to exit the menu structure and enter the run mode Flex Pro Configuration Display Language Set Password Display Rate Esc Reset to Default Display Language English Spanish German Done French Display La...

Страница 13: ...display may be toggled through Speed RPM and your selected Display Rate by pressing the right arrow button Press MENU button to enter the menu structure Select Configuration and Press ENTER button Se...

Страница 14: ...set Set FVS Max Flowrate Input Max Flowrate Flowrate ML min Press ENTER to set 0000 0 1 Contact Input Close Stop Pump Open Stop Pump Input Time Delay OFF 000 Range 1 255 sec Disable 00 0 Input Setup 4...

Страница 15: ...Press ENTER button Press UP or DOWN arrow to scroll through 0 9 on selected digit Press RIGHT arrow to scroll over to next digit to right If you pass your desired digit you can easily scroll back by c...

Страница 16: ...ck out of the menu structure To do this you must select Esc at the bottom of every screen menu until you see the Run Mode screen displayed Tip The Manual Speed Adjust mode can be combined with Contact...

Страница 17: ...creen Continue this process until all four screens have been configured If you used short cut to enter 4 20 mA input setup press and hold the Mode button until the Run Mode screen is displayed If you...

Страница 18: ...ut is displayed in the top line of the display To configure the pump navigate to 0 10 VDC Input menu by using the short cut method described at the beginning of the section or by pressing MENU button...

Страница 19: ...RIGHT ARROW to select the digit to change press UP or DOWN arrow to scroll through 0 9 on selected digit Press enter to save changes and move to the next input screen To input flow rate values press...

Страница 20: ...an easily scroll back by continuously pressing the RIGHT button Press ENTER to save the changes Continue this process until all three screens have been configured If you used the short cut to enter Pu...

Страница 21: ...e screens have been configured If you used the short cut to enter Manual Cycle Adjustment setup press and hold Mode button until Run Mode screen is displayed If you used the Menu button to navigate to...

Страница 22: ...croll over to next digit to the right If you pass your desired digit you can easily scroll back by continuously pressing RIGHT button Press ENTER to save the changes Continue this process until two sc...

Страница 23: ...digit Press RIGHT arrow to scroll over to next digit to the right If you pass your desired digit you can easily scroll back by continuously pressing RIGHT button Press ENTER to save the changes Conti...

Страница 24: ...desired digit you can easily scroll back by continuously pressing RIGHT button Press ENTER to save the changes Continue this process until all four screens have been configured If you used the short...

Страница 25: ...prevent false triggering due to flickering high speed electrical switches a trigger delay time can be configured to delay the pump command The delay time unit of measure is seconds A two second delay...

Страница 26: ...value of 000 seconds disables FVS system If a FVS alarm occurs the pump will stop send an external signal if setup and the screen will flash FVS with an alarm icon To clear the FVS alarm you must pres...

Страница 27: ...Chemicals with a conductivity of less than 430 microsiemens will not be detected This patented system is capable of detecting the presence of a large number of chemicals including Sodium Hypochlorite...

Страница 28: ...s menu setting will return to the previous setting when REMOTE ONLY or DISABLED is selected Input Setup Input Modes Contact Input Set FVS Esc Hidden Set Rev Alarm Set TFD Remote Local Remote Local Rem...

Страница 29: ...top Frequency Mode Cycle Timer Mode Dispensing Mode Manual Dosing Prop Dosing 0 10 VDC Mode Pulse Mode Disable FVS TFD Pump Run Stop 4 20mA Mode Manual Mode Frequency Mode Cycle Timer Mode Dispensing...

Страница 30: ...Output 4 mA 100 Pump Output 20 mA Signal Output Frequency Output Disable Done 4 20 mA Output Default 4 20 mA output settings shown Signal Output Disable Done 4 20 mA Output Default Frequency Hz output...

Страница 31: ...sembly especially when injecting fluids that calcify such as sodium hypochlorite These lime deposits and other build ups can clog the fitting increasing the back pressure at the pump reducing tube lif...

Страница 32: ...y clean the Pump Head and Rotor The Rotor can be removed by pulling it straight out After the cleaning process push the Rotor back on the shaft See the drawing above for proper assembly Be sure the fr...

Страница 33: ...de discharge fitting into pump head tongue and groove Once discharge fitting is secured in pump head stop pump by pressing STOP button Replace pump head cover Pump will ask you if the tube was replace...

Страница 34: ...4 tri clamp Sanitary Fitting Flex A Prene NEE 0 093 ID Tube Assembly Quick Disconnect Flex A Prene NGG 0 187 ID A3 SNGG T A3 MNGG T A3 BNGG T A3 CNGG T 1 1 1 1 1 1 1 1 4 Tube Assembly 3 8 OD tube com...

Страница 35: ...ID Tube Assy 1 2 hose barb Multi Tube Flex A Thane GK GK 38 38 ID Tube Assy 1 2 Male NPT Multi Tube Flex A Thane GH GH 25 25 ID Tube Assy 1 2 Male NPT Multi Tube Flex A Thane GK GK 38 38 ID A4 BGHH T...

Страница 36: ...K MTK MGK MNGG MNEE MG2G Suction lift 3 ft 0 500 1000 1500 2000 2500 0 30 60 90 125 Motor RPM Flex Pro Model M 3 output of water vs motor rpm MNH MNJ MNK MTK MGK MNGG MNEE MG2G Suction lift 3 ft 0 200...

Страница 37: ...Model M 4 output of 200 cP fluid vs motor speed BNH BNJ BNL BNP MTK MGK Suction lift 3 ft 0 2000 4000 6000 8000 10000 12000 0 25 50 75 100 Motor Speed Flex Pro Model M 4 output of water vs motor speed...

Страница 38: ...Flex Pro Page 38 Intentionally Left Blank...

Страница 39: ...Page 39 Flex Pro Intentionally Left Blank...

Страница 40: ...injecting various chemicals especially those considered hazardous or dangerous Eye protection must be worn when working around this product or any other metering type of pump Should it become necessa...

Отзывы: