3.0
MATERIALS OF CONSTRUCTION
3.1
Wetted Components
3.2
Non-Wetted Components
Pump Tube Assembly
Tubing
®
®
®
Flex-A-Prene , Flex-A-Thane , Flex-A-Chem
Adapter Fittings
PVDF
Enclosure
®
Valox (PBT) & PA12
Pump Head
®
Valox (PBT)
Pump Head Cover
Polycarbonate
Permanently lubricated sealed motor shaft support ball bearing.
Cover Screws
Stainless steel, polypropylene cap
Roller Assembly
Rotor
®
Valox (PBT)
Rollers
Nylon
Roller Bearings
Bronze
TFD+ System Sensor
Polysulfone (PES)
Power Cord
3 conductor, SJTW-A water-resistant
Tube Installation Tool
GF nylon
Mounting Brackets and Hardware
316 stainless steel screws
GF nylon bracket
4.1
Agency Listings
4.0
FEATURES
>
Tube Failure Detection (TFD+) senses tube failure and shuts off the pump. No false triggering.
>
Heavy duty display shield protects pump controls.
>
Remote Start/Stop, which is one non-powered dry contact closure.
>
Compatible with Blue-White Industries, Ltd.’s output Flow Verification Sensor (FVS) system.
>
Relay outputs include a single 250V/ 3A and a single solid state.
>
Self-priming (even against maximum line pressure), which means no required bypass valves, and it cannot
vapor lock or lose prime.
>
SCADA Inputs include: 4-20mA
Symbol
Description
Warning (Risk of electric shock)
Caution (Refer to the user’s guide)
Ground, Protective Conductor Terminal
ENCLOSURE RATING
NEMA 4X
Constructed for either indoor or outdoor use to provide a degree of protection to personnel against incidental
contact with enclosed equipment; to provide a degree of protection against falling dirt, rain, sleet, snow,
windblown dust, splashing water, and hose-directed water; and that will be undamaged by external formation
of ice on enclosure.
IP66
No ingress of dust; complete protection against contact. Water projected in powerful jets against enclosure
from any direction shall have no harmful effects.
!
This pump is ETL listed to conforms to the following: UL Standard 778 as a motor operated water pump.
CSA Standard C22.2 as process control equipment
R
Certified to
NSF/ANSI Standard 61
This pump is certified to NSF/ANSI Standard 61- Drinking Water System Components - Health Effects
This pump complies to the Machinery Directive 98/37/EC, BS, EN 60204-1, Low Voltage Directive