The pump tube assembly will eventually become non-operational if it is not regularly inspected and replaced. The
tube life is affected by many factors, such as the type of chemical being pumped, the amount of back pressure,
the motor revolutions per minute (RPM), and temperature.
Use extreme caution when replacing the pump tube.
Do not place your fingers near the
rollers.
12.0 TUBE REPLACEMENT
Prior to service, pump clean water through the pump and suction / discharge line to remove
any chemical.
Always wear protective clothing, face shield, safety glasses and gloves when working on or
near your metering pump. Additional precautions should be taken depending on solution
being pumped. Refer to MSDS precautions from your solution supplier.
Use the provided Tube Installation Tool to leverage tubing into the pump head.
Do not use
your fingers.
Safety first
.
Remove the pressure
. Relieve (remove) the system pressure on the
discharge and suction side of the pump. Failure to do so will cause the solution to squirt
when disconnecting the tube connections.
12.2 Tube Removal
1. Disconnect the system plumbing from the pump tube
adapters.
2. Press the Start/Stop key to stop the pump.
3. Remove the three black thumb screws from the front of
the pump head cover by unscrewing counterclockwise.
Remove the pump head cover by pulling straight out.
12.1 Provided Tool
Tube Installation Tool
90002-278
CAUTION
!
CAUTION
!
CAUTION
!
CAUTION
!
CAUTION
!
4.
Set the motor speed to 10%.
Press the Start/Stop key to start the pump.
5. With the pump running, pull the inlet (suction) fitting out of the pump head. Guide the tube counterclockwise
away from the rollers. Pull the outlet (discharge)fitting out of the pump head.
6. Press the Start/Stop key to stop the pump.