1
Specifications
4
Blue Seal Evolution Series GT45 / GT46 / GT60
©
Moffat Ltd, January 2007
Revision 1/
Gas supply (Non-UK models)
Natural Gas
LPG
Main Burners
3.10mm
1.90mm
Pilot Burners (Non-UK models)
0.62mm
0.35mm
Pilot Burners (UK models)
0.45mm
0.30mm
GT45
GT46
GT60
Oil capacity
20l
16kg
13l (per tank)
10.5kg (per tank)
31.5 l
25 kg
Useable internal
dimensions of tank
(width x length)
365mm x 385mm 175mm x 385mm 545mm x 385mm
Useable depth of oil
80mm
80mm
80mm
Combustible surface
Non-Combustible surface
Rear
50mm
0mm
Left-hand side
50mm
0mm
Right-hand side
50mm
0mm
Top *
610mm
610mm
Front **
600mm
600mm
* Top clearance is from flue outlet to any above surface
** Front clearance is in order to facilitate easy operation, drainage and
servicing of the appliance
Installation clearances
Tank capacity
Injector sizes
Natural Gas
LP Gas (Propane)
Input Rating
90 MJ/hr
90 MJ/hr
(N.H.G.C.)
(85,300 Btu/hr)
(85,300 Btu/hr)
Supply Pressure
1.13 - 2.00 kPa
2.75 - 3.00 kPa
(4.5” - 8.0” w.c.)
(11” - 12” w.c.)
0.98 kPa
2.50 kPa
(3.9” w.c.)
(10.0” w.c.)
Gas Connection
¾” BSP Male
Burner Operating Pressure
Gas supply (UK models)
Natural Gas (G20)
Propane (G31)
Heat Input (nett)
22.5 kW
22.5 kW
Gas Rate
1.75 kg/hr
Supply Pressure
20 mbar
37 mbar
Burner Operating Pressure
9.8 mbar
25 mbar
Gas Connection
3
/
4
” BSP Male
2.26 m
3
/hr