background image

 

W

This grill is for outdoor use only, and should not be used in a building, garage or any other enclosed area.  

 

W

Do NOT operate, light or use this appliance within ten feet (3.05 m) of walls, structures or buildings.

 

W

For residential use only. This grill is NOT for commercial use.

 

W

This grill is not intended for and should never be used as a heater. TOXIC fumes can accumulate and cause asphyxiation.

 

W

This grill is safety certified for use in the United States and/or Canada only. Do NOT modify for use in any other location. Modification will result in a 
safety hazard and will void your warranty.

 

W

This grill, from the factory, is for use with liquid propane (LP) gas only. The conversion to or attempted use of natural gas in this LP gas grill is 
dangerous, may cause bodily harm and will void your warranty.

 

W

This grill, from the factory, is for use with LP gas. The natural gas conversion kit model number VFK1702W may be used to convert your grill to natural 
gas. The use of any other conversion kit is dangerous, may cause bodily harm and will void your warranty.

 

W

LP gas characteristics: 
a.  LP gas is flammable and hazardous if handled improperly.  Become aware of the characteristics before using any LP gas product.  
b.  LP gas is explosive under pressure, heavier than air, and settles/pools in low areas. 
c.  LP gas in its natural state has no odor.  For your safety, an odorant is added that smells like rotten cabbage.  
d.  Contact with LP gas can cause freeze burns to skin.

 

W

Natural gas ( NG) characteristics: 
a.  NG is flammable and hazardous if handled improperly.  Become aware of the characteristics before using any NG product.  
b.  NG is explosive under pressure, heavier than air, and settles/pools in low areas. 
c.  NG in its natural state has no odor.  For your safety, an odorant is added that smells like rotten cabbage.  
d.  Contact with NG can cause freeze burns to skin.

 

W

Apartment dwellers: Check with management to learn the requirements and fire codes for using a LP gas grill in your apartment complex. If allowed, 
use outside on the ground floor with a ten foot (3.05 m) clearance from any structure. Do NOT use on or under balconies.

 

W

LP gas cylinder needed to operate. Only cylinders marked “propane” may be used.  

 

W

The LP gas cylinder must be constructed and marked in accordance with the 

Specifications for LP-gas Cylinders

 of the U.S. Department of 

Transportation (D.O.T.) or the National Standard of Canada,

 CAN/CSA-B339, Cylinders, Spheres and Tubes for the Transportation of Dangerous Goods; 

and Commission.

  

 

W

LP gas cylinder must be arranged for vapor withdrawal.

 

W

The LP gas cylinder must have a listed overfilling prevention device (OPD).

 

W

Only use LP gas cylinders equipped with a cylinder connection device compatible with the connection for outdoor cooking appliances.

 

W

The LP gas cylinder must have a cylinder collar to protect the cylinder valve.

 

W

Never use a LP gas cylinder with a damaged body, valve, collar or footing.  

 

W

Dented or rusted LP gas cylinders may be hazardous and should be checked by your LP gas supplier prior to use.

 

W

The LP gas cylinder should not be dropped or handled roughly. 

 

W

LP gas cylinders must be stored outdoors out of the reach of children and must not be stored in a building, garage or any other enclosed area. Your 
cylinder must never be stored where temperatures can reach over 125°F. 

 

W

Do NOT insert any tool or foreign object into the valve outlet or safety relief valve. You may damage the valve and cause a leak. Leaking propane may 
result in an explosion, fire, severe personal injury or death.

 

W

Do NOT block holes in sides or back of grill.

 

W

Never keep an LP gas cylinder in a hot car or trunk. Heat will cause the gas pressure to increase, which may open the relief valve and allow gas to 
escape.

 

W

Place dust cap on cylinder valve outlet whenever the cylinder is not in use. Only install the type of dust cap on the cylinder valve outlet that is provided 
with the cylinder valve. Other types of caps or plugs may result in leakage of propane.

 

W

If grill is not in use, the gas must be turned off at the supply cylinder and disconnected.

 

W

Do NOT store a spare LP gas cylinder under or near this appliance.

 

W

Never fill the cylinder beyond 80 percent full.

 

W

A fire causing serious injury or damage to property may occur if the above is not followed exactly. 

 

W

Never attempt to attach this grill to the self-contained LP gas system of a camper trailer, motor home or house.  

 

W

Never use charcoal, lighter fluid, lava rocks, gasoline, kerosene or alcohol with this product.

 

W

Your grill has been checked at all factory connections for leaks.  Recheck all connections as described in the “Operating Instructions” section, as 
shipping can loosen connections.  

 

W

Check for leaks even if your unit was assembled for you by someone else.

 

W

Do NOT operate if a gas leak is present. Gas leaks may cause a fire or explosion.

 

W

You must follow all instructions in “Checking for Leaks” section before operating. To prevent fire or explosion hazard when testing for a leak:
a.  Always perform a leak test before lighting the grill and each time the cylinder is connected for use.
b.  No smoking. Do NOT use or permit sources of ignition in the area while conducting a leak test. 
c.  Conduct the leak test outdoors in a well-ventilated area.  
d.  Do NOT use matches, lighters, or a flame to check for leaks. 
e.  The use of alcohol, prescription or non-prescription drugs may impair the consumer’s ability to properly assemble or safely operate the appliance.
f.  Strong odors, colds, sinus congestion, etc. may prevent the detection of propane. Use caution and common sense when testing for leaks. 
g.  Do NOT use grill until any and all leaks are corrected.   

LP: If you are unable to stop a leak, disconnect the LP gas supply.  Call a gas appliance serviceman or your local LP gas supplier. 
NG: If you are unable to stop a leak, turn off the main valve on the NG supply line.  Call a gas appliance serviceman or your local NG supplier.

 

W

NG: The appliance and its individual shutoff valve must be disconnected from the gas supply piping system during any pressure testing of that system 
at pressure in excess of 1/2 psig (3.5 kpa).

Important Safeguards

Warning

Содержание GBC1705WV

Страница 1: ...a for RevoAce Inc Limited Hong Kong China Outdoor LP Gas Barbecue Grill Model No GBC1705WV DANGER Never operate this appliance unattended FOR YOUR SAFETY For Outdoor Use Only outside any enclosure FOR YOUR SAFETY 1 Improper installation adjustment alteration service or maintenance can cause injury or property damage 2 Read the installation operation and maintenance instructions thoroughly before i...

Страница 2: ...hazardous and should be checked by your LP gas supplier prior to use W W The LP gas cylinder should not be dropped or handled roughly W W LP gas cylinders must be stored outdoors out of the reach of children and must not be stored in a building garage or any other enclosed area Your cylinder must never be stored where temperatures can reach over 125 F W W Do NOT insert any tool or foreign object i...

Страница 3: ...tional vehicles W W When cooking fire extinguishing materials should be readily accessible In the event of an oil grease fire do NOT attempt to extinguish with water Use type BC dry chemical fire extinguisher or smother with dirt sand or baking soda W W Do NOT use grill in high winds W W Never lean over the grill when lighting W W Do NOT leave a lit grill unattended Keep children and pets away fro...

Страница 4: ...bly G1305 070 10 Igniter B0217 I01 11 Control Knob Bezel 2 G1205 200 12 Control Knob 2 G0900 080 13 Regulator Hose Assembly G1405 090 14 QCC Clip G1205 220 15 Lighting Rod B0223 B01 16 Grease Cup Support B0220 D01 17 Grease Cup B0219 D01 18 Upper Cart Frame 2 G1205 100 19 Cart Frame Support Wire G1306 130 20 Rear Cart Frame Support G1205 140 21 LP Gas Tank Retainer Wire G1205 150 22 Upper Front Pa...

Страница 5: ...ten all hardware Be careful not to over tighten That could damage surfaces or strip threads 4 For best results complete each step in the order presented To complete assembly you will need 1 Leak detection solution instructions on how to make the solution are included in the Operating Instructions section of this manual LP 1 Precision filled LP gas grill tank with Acme Type 1 external threaded valv...

Страница 6: ...6 Attach Cart Frame Support Wire 6 G x 1 Attach Front Panels and Rear Cart Support 5 Attach Handle Control Knobs and Temperature Gauge 8 D x 2 Attach LP Gas Tank Retainer Wire 7 H x 2 B x 11 I x 2 ...

Страница 7: ...7 Attach Grill Body Assembly and Lighting Rod 9 Secure QCC Clip 10 Attach Side Shelves 12 Attach Condiment Basket 11 E x 1 D x 5 H x 2 B x 1 C x 4 ...

Страница 8: ...8 Insert Grease Cup Support and Grease Cup 13 Insert Warming Rack 14 Insert Heat Plates and Cooking Grids 15 Natural gas conversion kit model no VFK1702W available at Walmart or www Walmart ca ...

Страница 9: ...installation Figure 1 5 If the burner venturi tube does not rest flush to the orifice as shown please contact 1 800 694 0013 for assistance Tank Gas Line Connection 1 Make 2 3 oz of leak detection solution by mixing one part liquid dishwashing soap with three parts water 2 Make sure control knobs are in the OFF position Figure 2 3 Connect LP gas tank per Installing LP Gas Tank section 4 LP Turn LP...

Страница 10: ...s turn control knobs to the OFF position a LP gas tank valve CLOSED or b NG main valve OFF Do NOT use water on a grease fire This can cause the grease to splatter and could result in serious burns bodily harm or other damage 2 Do NOT leave grill unattended while preheating or burning off food residue on HIGH If grill has not been cleaned a grease fire can occur Flare ups are a part of cooking meat...

Страница 11: ... exclusion and limitations may not apply to everyone RA does not authorize any person or company to assume for it any other obligation or liability in connection with the sale installation use removal return or replacement of its equipment and no such representations are binding on RA RevoAce Inc Limited Hong Kong China 1 800 694 0013 Cleaning Main Burner 1 LP Turn LP gas tank valve to CLOSED NG T...

Страница 12: ...f burner to valve Reengage burner and valve Spider webs or insect nest in venturi Clean burner venturi tube Burner ports clogged or blocked Clean burner ports Sudden drop in gas flow or reduced flame height LP Out of gas Exchange refill or replace LP gas tank NG No main line pressure Call your natural gas provider to inspect natural gas line LP Overfilling prevention device may have been activated...

Отзывы: