background image

12 

Troubleshooting

Problem

Possible Cause

Prevention/Cure

Burner will not light using ignitor

LP gas tank valve is closed 
NG main valve is closed

LP: Make sure regulator is securely attached to the LP gas tank per “Installing 
LP Gas Tank,” then turn LP gas tank valve to “OPEN” 
NG: Make sure regulator and NG main line are securely attached per “Installing 
Natural Gas Line,” then turn NG main valve to “ON”

LP gas tank is low or empty

Exchange, refill or replace LP gas tank

LP gas / NG leak

1.  LP:

 Turn LP gas tank valve to “CLOSED” 

NG:

 Turn natural gas main valve to “OFF”

2 .  Wait 5 minutes for gas to clear
3 .  Follow “Checking for Leaks” section

Battery needs to be changed

Replace the “AA” battery (follow assembly step for inserting battery)

Wires or electrode covered with cooking residue

Clean wire and/or electrode with rubbing alcohol

Electrode and burners are wet

Wipe dry with cloth

Electrode cracked/broken - sparks at crack

Replacement part(s) may be needed - contact Customer Care at 1 .800 .694 .0013

Wire loose or disconnected

Reconnect wire or replacement part(s) may be needed - contact Customer Care 
at 1 .800 .694 .0013

Wire is shorting (sparking) between ignitor and electrode Replacement part(s) may be needed - contact Customer Care at 1 .800 .694 .0013
Bad ignitor

Replacement part(s) may be needed - contact Customer Care at 1 .800 .694 .0013

Burner will not light with match

No gas flow

LP: Check if LP gas tank is empty

A . If empty, exchange, refill or replace LP gas tank
B .  If LP gas tank is not empty, refer to “Sudden drop in gas flow or reduced 

flame height” (see below)

NG: Check if NG main valve is connected

A .  Make sure regulator and NG main line are securely attached, then turn NG 

main valve to “OPEN”

B .  If NG main valve is “ON,” then refer to “Sudden drop in gas flow or reduced 

flame height” (see below)

LP gas tank is low or empty

Exchange, refill or replace LP gas tank

LP gas / NG leak

1.  LP:

 Turn LP gas tank valve to “CLOSED .” 

NG:

 Turn natural gas main valve to “OFF”

2 .  Wait 5 minutes for gas to clear
3 .  Follow “Checking for Leaks” section

Coupling nut and regulator not fully connected

Turn the coupling nut about one-half to three quarters additional turn until solid 
stop . 

Tighten by hand only - do NOT use tools.

Obstruction of gas flow

1 .  Clear burner tubes
2 .  Check for bent or kinked hose

Disengagement of burner to valve

Reengage burner and valve

Spider webs or insect nest in venturi

Clean burner/venturi tube

Burner ports clogged or blocked

Clean burner ports

Sudden drop in gas flow or reduced flame height

LP: Out of gas

Exchange, refill or replace LP gas tank

NG: No main line pressure

Call your natural gas provider to inspect natural gas line

LP: Overfilling prevention device may have been 
activated

1 .  Turn control knobs to “  OFF”
2 .  Wait 30 seconds and light grill
3 .   If flames are still too low, reset the overfilling prevention device:

a .  Turn control knob(s) “  OFF”
b .  Turn LP gas tank valve to “CLOSED”
c .  Disconnect regulator
d .  Turn control knobs to   (HIGH)
e .  Wait 1 minute
f .  Turn control knobs to “  OFF”
g .  Reconnect regulator and leak check connections, being careful not to 

fully open valve

h .  Light grill per “Lighting” section

Irregular flame pattern, flame does not run the full 

length of burner

Burner ports are clogged or blocked

Clean burner ports

Flame is yellow or orange

New burner may have residual manufacturing oils

Burn grill for 15 minutes on    (HIGH) with the lid closed

Spider webs or insect nest in venturi

Clean venturi

Food residue, grease, etc . on burners

Clean burner

Poor alignment of valve to burner/venturi tube

Ensure burner/venturi tube is properly engaged with valve

Flame goes out

High or gusting winds

Do not use grill in high winds

Low on LP Gas

Exchange, refill or replace LP gas tank

Overfilling prevention device may have been activated

Refer to “Sudden drop in gas flow or reduced flame height” (see above)

Flare-up

Grease buildup

Remove and clean all grill parts per “Cleaning and Care” section

Excess fat in meat

Trim fat from meat before grilling

Excessive cooking temperature

Adjust to lower cooking temperature

Persistent grease fire

Grease trapped by food buildup around burner system

1 .  Turn control knobs to “  OFF”

2.  LP:

 Turn LP gas tank valve to “CLOSED” 

NG:

 Turn natural gas main valve to “OFF”

3 .  Leave lid in closed position and let fire burn out
4 .  After grill cools, remove and clean all parts per “Cleaning and Care” section

Flashback (fire in burner tube(s))

Burner and/or burner/venturi tube are blocked

Clean burners and/or burner/venturi tube(s)

Inside of lid is peeling (like paint peeling)

The lid is stainless steel, not painted

Grease buildup has turned to carbon and is flaking off – clean thoroughly per 
“Cleaning and Care” section

The lid is coated/painted

Grease buildup has turned to carbon and is flaking off – clean thoroughly per 
“Cleaning and Care” section

Содержание GBC1705WV

Страница 1: ...a for RevoAce Inc Limited Hong Kong China Outdoor LP Gas Barbecue Grill Model No GBC1705WV DANGER Never operate this appliance unattended FOR YOUR SAFETY For Outdoor Use Only outside any enclosure FOR YOUR SAFETY 1 Improper installation adjustment alteration service or maintenance can cause injury or property damage 2 Read the installation operation and maintenance instructions thoroughly before i...

Страница 2: ...hazardous and should be checked by your LP gas supplier prior to use W W The LP gas cylinder should not be dropped or handled roughly W W LP gas cylinders must be stored outdoors out of the reach of children and must not be stored in a building garage or any other enclosed area Your cylinder must never be stored where temperatures can reach over 125 F W W Do NOT insert any tool or foreign object i...

Страница 3: ...tional vehicles W W When cooking fire extinguishing materials should be readily accessible In the event of an oil grease fire do NOT attempt to extinguish with water Use type BC dry chemical fire extinguisher or smother with dirt sand or baking soda W W Do NOT use grill in high winds W W Never lean over the grill when lighting W W Do NOT leave a lit grill unattended Keep children and pets away fro...

Страница 4: ...bly G1305 070 10 Igniter B0217 I01 11 Control Knob Bezel 2 G1205 200 12 Control Knob 2 G0900 080 13 Regulator Hose Assembly G1405 090 14 QCC Clip G1205 220 15 Lighting Rod B0223 B01 16 Grease Cup Support B0220 D01 17 Grease Cup B0219 D01 18 Upper Cart Frame 2 G1205 100 19 Cart Frame Support Wire G1306 130 20 Rear Cart Frame Support G1205 140 21 LP Gas Tank Retainer Wire G1205 150 22 Upper Front Pa...

Страница 5: ...ten all hardware Be careful not to over tighten That could damage surfaces or strip threads 4 For best results complete each step in the order presented To complete assembly you will need 1 Leak detection solution instructions on how to make the solution are included in the Operating Instructions section of this manual LP 1 Precision filled LP gas grill tank with Acme Type 1 external threaded valv...

Страница 6: ...6 Attach Cart Frame Support Wire 6 G x 1 Attach Front Panels and Rear Cart Support 5 Attach Handle Control Knobs and Temperature Gauge 8 D x 2 Attach LP Gas Tank Retainer Wire 7 H x 2 B x 11 I x 2 ...

Страница 7: ...7 Attach Grill Body Assembly and Lighting Rod 9 Secure QCC Clip 10 Attach Side Shelves 12 Attach Condiment Basket 11 E x 1 D x 5 H x 2 B x 1 C x 4 ...

Страница 8: ...8 Insert Grease Cup Support and Grease Cup 13 Insert Warming Rack 14 Insert Heat Plates and Cooking Grids 15 Natural gas conversion kit model no VFK1702W available at Walmart or www Walmart ca ...

Страница 9: ...installation Figure 1 5 If the burner venturi tube does not rest flush to the orifice as shown please contact 1 800 694 0013 for assistance Tank Gas Line Connection 1 Make 2 3 oz of leak detection solution by mixing one part liquid dishwashing soap with three parts water 2 Make sure control knobs are in the OFF position Figure 2 3 Connect LP gas tank per Installing LP Gas Tank section 4 LP Turn LP...

Страница 10: ...s turn control knobs to the OFF position a LP gas tank valve CLOSED or b NG main valve OFF Do NOT use water on a grease fire This can cause the grease to splatter and could result in serious burns bodily harm or other damage 2 Do NOT leave grill unattended while preheating or burning off food residue on HIGH If grill has not been cleaned a grease fire can occur Flare ups are a part of cooking meat...

Страница 11: ... exclusion and limitations may not apply to everyone RA does not authorize any person or company to assume for it any other obligation or liability in connection with the sale installation use removal return or replacement of its equipment and no such representations are binding on RA RevoAce Inc Limited Hong Kong China 1 800 694 0013 Cleaning Main Burner 1 LP Turn LP gas tank valve to CLOSED NG T...

Страница 12: ...f burner to valve Reengage burner and valve Spider webs or insect nest in venturi Clean burner venturi tube Burner ports clogged or blocked Clean burner ports Sudden drop in gas flow or reduced flame height LP Out of gas Exchange refill or replace LP gas tank NG No main line pressure Call your natural gas provider to inspect natural gas line LP Overfilling prevention device may have been activated...