background image

20

 

 

 
2.    Uneven bake side to side 

a)    Not level side to side 
b)    Oven burner, bottom or baffles improperly installed 
c)    Warped pans 

 
3.    Uneven bake front to rear 

a)  Overactive flue 
b)    Not level front to back; check casters and legs 
c)    Door not closing properly 

 
4.    Dried out products 
 

a)    Too low temperature (overcooking) 
b)  Too long baking time 
c)    Thermostat calibration 

 
5.  Pilot outage 

a)    Pilot flame to low 
b)    Restriction in pilot orifice 
c)    Problem with shutoff valve 
d)    Possible fluing problems 
e)  Low pressure 
f)      Improper gas line sizing 
g)    Burner box cover not properly installed 
h)    Oven cavity requires resealing 

 

TOP BURNER OPERATION

 

1.  Improper burner combustion 

Excessive valve handle temperatures 
Sticking top burner valves 

a)  Improper ventilation 
b)    Poor door fit 
c)    Oven door left open 
d)    improper use of excessively large pans or pots 

 
2.  Poor ignition 

a)  Insufficient input 
b)  Poor air-gas adjustment 
c)    Restriction in pilot orifice 
d)    Restriction in main burner ignition port 

 

 

 

 

Limited Warranty 

 

BLUE FLAME Products warrants to the original owner/user that any unit manufactured by BLUE FLAME Products 
(“the products”) shall be free of defects in material or workmanship under normal and proper use and maintenance 
service as specified by BLUE FLAME  Products and upon proper installation (not to exceed 120 days from date of 
original shipment) and start-up in accordance with the instruction manual supplied with the Product.   

The obligation of BLUE FLAME Products and the rights and remedies of the owner/user under this warranty 
are exclusively limited to (1) the repair or replacement, including labor charges, of parts or assemblies that in 
BLUE FLAME Products opinion are defective within one year after the  original date of installation; 

The labor 

warranty shall include

 

standard straight time labor charges at the product location only and shall exclude charges for 

travel time, mileage or other premium

 

charges. Any labor service required to fulfill the warranty obligation must be 

performed by a service company qualified and accepted by BLUE  FLAME Products.

 

 
This warranty does not include parts or labor coverage for component failure or other damage resulting from: 
 

• External electrical power failure or miswiring to Product for any reason. 
• Adverse operating conditions as set forth in the owner/user manual for the Product. 

Содержание BFR-24-4

Страница 1: ...Rosecrans Ave Gardena CA 90248 USA Tel 1 866 677 8500 1 310 808 0102 Fax 1 310 808 0242 1 310 808 0262 WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DA...

Страница 2: ...NSTALL GAS EQUIPMENT WHO SHOULD PERFORM THE INITIAL FIELD START UP AND ADJUSTMENTS OF THE EQUIPMENT COVERED BY THIS MANUAL POST IN A PROMINENT LOCATION THE INSTRUCTIONS TO BE FOLLOWED IN THE EVENT THE...

Страница 3: ...D36 6X H42 3 471 214 BFR 60 10 10 top burner range two 36 oven 60 366 000 NG 326 000 LP W63 5 X D36 6X H42 3 764 347 BFR 60 24G 6 top burner range one 24 top griddle two 36 oven 60 306 000 NG 272 000...

Страница 4: ...PPED FOR NATURAL GAS for conversion to LP gas please see gas conversion instruction manual attached Orifices necessary for LP propane natural conversion are provided Please refer to page 3 the orifice...

Страница 5: ...ments do not agree do not proceed with the installation Contact your dealer or company immediately LOCATION The appliance must be installed under a ventilation hood The equipment area must be kept fre...

Страница 6: ...lied by CHEF N SAVE that complies with the Standard for Connectors for Movable Gas Appliances ANSI Z21 69 CSA 6 16 and a quick disconnect device that complies with the Standard for Quick Disconnect De...

Страница 7: ...rate instructions for installing casters to the range are included with the casters Note If the range is installed on casters and is moved for any reason it is recommended that the range be leveled fr...

Страница 8: ...crating materials 2 Assemble the required components as shown in Fig s 2 and 3 and 4 3 Tighten the four screws to secure the shelf 4 Lift the assembly up sliding the channels into the space provided...

Страница 9: ...9 5 Install four 10 sheet metal screws 2 to each channel leg Fig 6 LEVELING Check the leveling of the range Place a level inside the oven cavity across the Fig 5 Fig 6...

Страница 10: ...e of obstructions Codes require that a gas shutoff valve be installed in the gas line ahead of the range Standard ranges are equipped with fixed burner orifices which coincide with installation elevat...

Страница 11: ...leak limiter on gas pressure regulator as obstruction may cause regulator to malfunction WARNING PRIOR TO LIGHTING CHECK ALL JOINTS IN THE GAS SUPPLY LINE FOR LEAKS USE SOAP AND WATER SOLUTION DO NOT...

Страница 12: ...commended that the flue gases be ventilated to the outside of the building through a ventilation system installed by qualified personnel From the termination of the flue to the filters of the hood ven...

Страница 13: ...be seasoned to do a good cooking job The metal surface of the griddle is porous Food tends to get trapped in these pores and stick therefore it is important to season or fill up these pores with cooki...

Страница 14: ...or griddle top burner valve ON to remove air from the gas line Turn burner valve OFF when gas begins to flow Nightly Shutdown 1 Turn burner valve OFF pilot will remain lit Complete Shutdown 1 Turn bu...

Страница 15: ...when gas begins to flow 9 Nightly Shutdown 10 Turn burner valve OFF pilot will remain lit 11 Complete Shutdown 12 Turn burner valve OFF pilot will remain lit 13 Turn main gas supply OFF OPEN TOP BURNE...

Страница 16: ...ional models 1 Turn main gas supply ON Wait 30 seconds and using a taper light broiler griddle pilot 2 If pilot fails to light turn main gas supply OFF Wait 5 minutes and repeat Steps 1 and 2 3 Turn b...

Страница 17: ...6 Replace lower panel 7 Turn thermostat to desired temperature 8 If the pilot becomes extinguished Wait 5 Minutes then repeat the above procedure Nightly Shutdown 1 Turn oven thermostat OFF Complete S...

Страница 18: ...e knobs to full ON After preheating for 5 minutes turn valves down until desired flame or heating level is achieved Position the removable broiler grid into one of the two slide positions depending on...

Страница 19: ...rning 1c Too much top heat a Insufficient ventilation b Improper fluing c Improper thermostat bypass setting d Thermostat out of calibration e Fluctuating gas pressure We all recognize however that re...

Страница 20: ...tured by BLUE FLAME Products the products shall be free of defects in material or workmanship under normal and proper use and maintenance service as specified by BLUE FLAME Products and upon proper in...

Страница 21: ...o event shall the user be entitled to recover incidental or consequential damages including but not limited to damages for inconvenience food loss rental or replacement equipment loss of profits or ot...

Страница 22: ...y Units are shipped from the factory equipped for use on natural gas Parts necessary for L P liquid propane are provided with the unit Please refer to page 5 the orifice size list when you do gas conv...

Страница 23: ...from half open to full open then screw in ensure fix well 13 1 Regulator convert for MR 6 GR24 G MR 6 GR24T G only Before installing the included convertible regulator unscrew the octagon cap You can...

Страница 24: ...h gas conversion label on appliance the position below Gas conversion label The position for gas conversion 16 Completed gas conversion Pictured is the plastic insert Pull off insert from octagon cap...

Отзывы: