background image

Fig. 7. Horizontal register plate with rear flue connection

Fig. 8. Horizontal register plate with top flue connection

Alternative

Soot Door

Positions

Register Plate

With Soot Door

Alternative

Soot Door

Positions

Register Plate

With Soot Door

®

INSTALLATION  INSTRUCTIONS

11

2. Store stand and Midi stand

Place the Stand on the hearth, with at least 100mm clear space 
behind it. Remove the button head hex screws from the side 
brackets. With 2 people, carefully lift the stove on to the stand such 
that the front end of the Air Control Rod is lowered down inside the 
stand. Take care not to bend or damage the Air Control Rod. 
Temporarily rest the stove on the stand in this position and pull the 
Air Control Rod through the hole in the front of the stand. Now 
move the stove towards you to align the slots in the side of the stand 
with the 6mm tapped holes in the base brackets. Fix in position with 
button head hex screws and replace the Air Control Knob.

PRE LIGHTING CHECK

Before initial lighting the following points should be checked:

1. The bottom grate bars must all be fitted and should move freely 
and easily when the riddling mechanism is operated.

2. The plates round the sides and back of the grate must be in 
position and sitting correctly.

3. The throat plate must be fitted in the roof of the appliance and 
should be checked to ensure that it has not become dislodged in 
transit. The method of location and positioning of the throat plate is 
shown in Fig. 4.

COMMISSIONING

On completion of the installation and after allowing a suitable period 
of time for the fire cement and mortar to dry out, the stove should 
be lit and checked to ensure that smoke and fumes are taken from 
the appliance up the chimney and emitted safely. Also check all joints 
and seals. On completion of the installation and commissioning 
please leave the operating instructions with the customer and advise 
them on the use of the appliance.

charnwood

Fig.6. Vertical register plate with bricked up fireplace

Register Plate

Soot Door

in side or rear

of Chimney

Fig. 9. Horizontal register plate with optional vertical rear flue connector

Alternative

Soot Door

Positions

Register Plate

With Soot Door

Содержание Charnwood Cove 2

Страница 1: ...Operating Installation Instructions charnwood 2 3 ...

Страница 2: ......

Страница 3: ...Clearing 6 Chimney Sweeping 7 Trouble Shooting 7 CO Alarm 8 If You Need Further Help 8 INSTALLATION INSTRUCTIONS Health Safety Precautions 9 CO Alarms 9 Specification 9 Chimney 9 Hearth Fire Surround 10 Connection to Flues 10 Soot Doors 10 Unpacking The Stove 10 Fitting The Stove To Its Stand 10 11 Pre Lighting Check 11 Commissioning 11 Clean Air Act Information 12 Dimensions 13 14 Parts Lists 15 ...

Страница 4: ... begins to require extra force then the cause must be investigated and corrected to prevent damage being caused to the stove Remember that the stove will be hot and is made from hard material Ensure that you have good balance before operating the fire When using the stove in situations where children aged and or infirm persons are present a fireguard must be used to prevent accidental contact with...

Страница 5: ...mmend the use of a stove pipe thermometer which may be purchased from your supplier or from Charnwood The Cove 2 blu is fitted with an air control stop for use in a smoke control area This stops the stove from burning too slowly REFUELLING Keep the firebox well filled but do not allow fuel to spill over the top of the fuel retainer Logs should be evenly distributed filling the firebed to give the ...

Страница 6: ...hen special high temperature paints are available from your supplier or from Charnwood Cleaning the Glass The glass in the door is a special ceramic glass which is able to withstand high temperatures Before cleaning the glass open the door and allow it to cool Clean the glass using a damp cloth and then wipe over with a dry cloth Any stubborn deposits on the glass may be removed with a proprietary...

Страница 7: ...guide wheel is recommended For prefabricated insulated chimneys the manufacturers instructions with regard to sweeping shouldbeconsulted TROUBLE SHOOTING Fire Will Not Burn Check that a the air inlet at the rear of the stove is not obstructed in any way b chimneys and flueways are clear c a suitable fuel is being used d there is an adequate air supply into the room e an extractor fan is not fitted...

Страница 8: ...om the Charnwood Customer Services department who will be pleased to give advice if necessary CAA AND SMOKE CONTROL The Clean Air Act 1993 and Smoke Control Areas Under the Clean Air Act local authorities may declare the whole or 8 charnwood part of the district of the authority to be a smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed ...

Страница 9: ...ctly or ensuring regular servicing and maintenance of the appliance and chimney system SPECIFICATIONS CHIMNEY In order for the appliance to perform satisfactorily the chimney height must not be less than 4 metres measured vertically from the outlet of the stove to the top of the chimney The minimum internal chimney sizes are as follows COVE 2 150mm diameter 6 inches or 150mm x 150mm COVE 3 180mm d...

Страница 10: ...e sealing face of the flue collar should be coated with fire cement before fixing to the body of the stove using the two screws provided The blanking plate must be removed sealed with fire cement and refitted care being taken to ensure that the fold on the clamping plate is in line with the lugs on the firebox as shown on the label on the clamping plate Ensure that the clamping plate does not prev...

Страница 11: ...ighting the following points should be checked 1 The bottom grate bars must all be fitted and should move freely and easily when the riddling mechanism is operated 2 The plates round the sides and back of the grate must be in position and sitting correctly 3 The throat plate must be fitted in the roof of the appliance and should be checked to ensure that it has not become dislodged in transit The ...

Страница 12: ... appliances are exempted bypublication on a list by Scottish Ministers under section 50 of the Regulatory Reform Scotland Act 2014 In Northern Ireland appliances are exempted by publication on a list by the Department of Agriculture Environment and Rural Affairs under Section 16 of the Environmental Better regulation Act Northern Ireland 2016 In Wales appliances are exempted by regulations made by...

Страница 13: ...D CENTRE STAND a b c d e 697 647 103 76 532 697 647 103 76 532 824 774 230 203 659 944 894 350 323 779 944 894 350 323 779 b c d e a FRONT VIEW SIDE VIEW BACK VIEW TOP VIEW 96 162 403 418 152 159 567 520 600 Optional vertical rear flue adaptor Optional external air manifold kit charnwood ...

Страница 14: ...IONS mm 1130 980 110 115 844 1130 980 110 115 844 1200 1150 280 285 1014 1330 1280 410 415 1144 1330 1280 410 415 1144 b c d e a a b c d e 179 191 441 178 619 439 585 113 660 Optional vertical rear flue adaptor FRONT VIEW SIDE VIEW BACK VIEW TOP VIEW Optional external air manifold kit charnwood ...

Страница 15: ... Door Catch 26 010 ST031 Door Catch Spacer 27 008 FFW015 M12 Double Coil Spring Washer 28 008 PX95 Door Riddling Ashpan Tool 29 008 BW39 S Hinge Pin Set 30 002 PY24 Hinge Post 31 004 PY25B Hinge Post Shim 0 9mm 32 004 PY25A Hinge Post Shim 2mm 33 008 AY37 Air Control Knob Item Part No Description 34 004 CY22S Secondary Air Inlet Flap 35 004 CY21 Air Bypass Slide 36 004 CY22P Primary Air Inlet Flap...

Страница 16: ...002 PX92 Door Knob Spindle 23 008 FFN001 M12 Half Nut 24 004 ST008 Tabbed Locking Washer 25 002 AY14 Door Catch Cam 26 010 ST031 Door Catch Spacer 27 008 FFW015 M12 Double Coil Spring Washer 28 008 PX95 Door Riddling Ashpan Tool 29 008 PV28 S Hinge Pin Set 2 Per Set 30 004 GV24 Rear Brick Joining Bracket 31 002 RY26 Hinge Post 32 004 RY25B Hinge Post Shim 0 9mm 33 004 RY25A Hinge Post Shim 2mm 34 ...

Страница 17: ...015 RXE44 CPD 2015 Fuel type WOOD LOGS WOOD LOGS Emission of CO in combustion products 0 10 0 10 Mean flue gas temperature 336 C 330 C Flue spigot temperature 403 C 396 C Space heating thermal output 8kW 12kW Energy efficiency 77 80 Minimum distance to combustible materials Side Rear 450mm 600mm 500mm 500mm Particles mg m ⁿ 15 14 Fulfilled requirements BStV of the City of Munich and the City of Re...

Страница 18: ......

Страница 19: ... e g i s t e r e d i n E n g l a n d N o 0 3 8 0 9 3 7 1 charnwood BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM T 4 4 0 19 8 3 5 3 7 7 7 7 F 4 4 0 19 8 3 5 3 7 7 8 8 C O N TA C T U S AT W W W C H A R N W O O D C O M y o u r p re m i e r d e a l e r ...

Отзывы: