background image

®

INSTALLATION  INSTRUCTIONS

9

HEALTH & SAFETY PRECAUTIONS

Please take care when installing the stove that the requirements of 
the Health and Safety at Work Act 1974 are met.

Some types of fire cement are caustic and should not be allowed to 
come into contact with the skin. In case of contact wash with plenty 
of water.

If there is a possibility of disturbing any asbestos in the course of 
installation then please use appropriate protective equipment.

There must be an adequate air supply into the room in which the 
appliance is installed to provide combustion air. The combustion air 
supply must be via a permanently open vent. The requirement for  
minimum free area is partly dependent on the design air 
permeability of the house. In older properties the air permeability 
will be above 5.0m³/(h.m²), but in some modern properties it may 
be less. The vent must be positioned such that it is not liable to 
blockage. Minimium areas are given in the following table: 

This stove is capable of intermittent operation, and is not suitable for 
use in a shared flue system.

A fixed ducted air supply may be used as an alternative to the 
traditional method of using a permanent open vent into a room to 
supply air for combustion.

External air supply kits are available please contact Charnwood for 
more information.

In addition to these instructions the requirements of BS.8303 and 
BSEN 15287-1:2007 must be fulfilled. Local Authority Bylaws and 
Building Regulations, including those referring to national and 
European Standards, regarding the installation of Solid Fuel burning 
appliances, flues and chimneys must also be observed.

CO ALARMS

Building regulations require that whenever a new or replacement 
fixed solid fuel or wood/biomass appliance is installed in a dwelling a 
carbon monoxide alarm must be fitted in the same room as the 
appliance. Further guidance on the installation of the carbon 
monoxide alarm is available in BS EN 50292:2002 and from the 
alarm manufacturer's instructions. Provision of an alarm must not be 
considered a substitute for either installing the appliance correctly or 
ensuring regular servicing and maintenance of the appliance and 
chimney system.

SPECIFICATIONS

CHIMNEY

In order for the appliance to perform satisfactorily the chimney 
height must not be less than 4 metres measured vertically from the 
outlet of the stove to the top of the chimney. The minimum internal 
chimney sizes are as follows:

COVE 2

 ........... 150mm diameter(6 inches) or 150mm x 150mm

COVE 3

............ 180mm diameter (7 inches) or 180mm x 180mm

These stoves are NOT to be used in a shared flue. If an existing 
chimney is to be used it must be swept and checked, it must be in 
good condition, free from cracks and blockages, and should not have 
an excessive cross sectional area. If you find that the chimney is in 
poor condition then expert advice should be sought regarding the 
necessity of having the chimney lined. If it is found necessary to line 
the chimney then a lining suitable for Solid Fuel must be used.

If there is no existing chimney then a prefabricated block chimney or 
a twin walled insulated stainless steel flue to BS EN15287-1:2007 
can be used either internally or externally. These chimneys must be 
fitted in accordance with the manufacturers instructions and Building 
Regulations.

Anki pumice liners or chimney blocks will give a highly insulated 
chimney which will work well with all fuels. For details ring Anki 
Chimney Systems on (01983) 527997.

Single wall flue pipe is suitable for connecting the stove to the 
chimney but is not suitable for using for the complete chimney.

If it is found that there is excessive draw in the chimney then a 
draught stabilizer should be fitted.

It is important that there is sufficient draw in the chimney and that 
the chimney does not suffer from down-draught. When the chimney 
is warm the draw should be not less than 0.05 inches water gauge 

Air Permeability

m³/(h.m²)

Minimum Vent Area cm²(in²)

Cove 2

Cove 3

> 5.0

19 (2.9)

40.7 (6.3)

<5.0

46.8 (7.3)

68.2 (10.6)

The outputs were obtained burning seasoned hardwood over a 1.5 hourly re-fuelling cycle.

Specification

Cove 2

Cove 3

Output kW

8.5

12.4

(BTU/h)

29,000

42,300

Mass (kg)

Low Stand

127

159

Low Arch Stand

127

159

Midi Stand

130

168

Store Stand

133

171

Centre Stand

146

187

Minimum Flue Draught 

12Pa

12Pa

Flue Gas Temp °C

336

330

Flue Gas Mass Flow G/S

6.8

8.6

Max Hearth Temp °C 

25

36

charnwood

Содержание Charnwood Cove 2

Страница 1: ...Operating Installation Instructions charnwood 2 3 ...

Страница 2: ......

Страница 3: ...Clearing 6 Chimney Sweeping 7 Trouble Shooting 7 CO Alarm 8 If You Need Further Help 8 INSTALLATION INSTRUCTIONS Health Safety Precautions 9 CO Alarms 9 Specification 9 Chimney 9 Hearth Fire Surround 10 Connection to Flues 10 Soot Doors 10 Unpacking The Stove 10 Fitting The Stove To Its Stand 10 11 Pre Lighting Check 11 Commissioning 11 Clean Air Act Information 12 Dimensions 13 14 Parts Lists 15 ...

Страница 4: ... begins to require extra force then the cause must be investigated and corrected to prevent damage being caused to the stove Remember that the stove will be hot and is made from hard material Ensure that you have good balance before operating the fire When using the stove in situations where children aged and or infirm persons are present a fireguard must be used to prevent accidental contact with...

Страница 5: ...mmend the use of a stove pipe thermometer which may be purchased from your supplier or from Charnwood The Cove 2 blu is fitted with an air control stop for use in a smoke control area This stops the stove from burning too slowly REFUELLING Keep the firebox well filled but do not allow fuel to spill over the top of the fuel retainer Logs should be evenly distributed filling the firebed to give the ...

Страница 6: ...hen special high temperature paints are available from your supplier or from Charnwood Cleaning the Glass The glass in the door is a special ceramic glass which is able to withstand high temperatures Before cleaning the glass open the door and allow it to cool Clean the glass using a damp cloth and then wipe over with a dry cloth Any stubborn deposits on the glass may be removed with a proprietary...

Страница 7: ...guide wheel is recommended For prefabricated insulated chimneys the manufacturers instructions with regard to sweeping shouldbeconsulted TROUBLE SHOOTING Fire Will Not Burn Check that a the air inlet at the rear of the stove is not obstructed in any way b chimneys and flueways are clear c a suitable fuel is being used d there is an adequate air supply into the room e an extractor fan is not fitted...

Страница 8: ...om the Charnwood Customer Services department who will be pleased to give advice if necessary CAA AND SMOKE CONTROL The Clean Air Act 1993 and Smoke Control Areas Under the Clean Air Act local authorities may declare the whole or 8 charnwood part of the district of the authority to be a smoke control area It is an offence to emit smoke from a chimney of a building from a furnace or from any fixed ...

Страница 9: ...ctly or ensuring regular servicing and maintenance of the appliance and chimney system SPECIFICATIONS CHIMNEY In order for the appliance to perform satisfactorily the chimney height must not be less than 4 metres measured vertically from the outlet of the stove to the top of the chimney The minimum internal chimney sizes are as follows COVE 2 150mm diameter 6 inches or 150mm x 150mm COVE 3 180mm d...

Страница 10: ...e sealing face of the flue collar should be coated with fire cement before fixing to the body of the stove using the two screws provided The blanking plate must be removed sealed with fire cement and refitted care being taken to ensure that the fold on the clamping plate is in line with the lugs on the firebox as shown on the label on the clamping plate Ensure that the clamping plate does not prev...

Страница 11: ...ighting the following points should be checked 1 The bottom grate bars must all be fitted and should move freely and easily when the riddling mechanism is operated 2 The plates round the sides and back of the grate must be in position and sitting correctly 3 The throat plate must be fitted in the roof of the appliance and should be checked to ensure that it has not become dislodged in transit The ...

Страница 12: ... appliances are exempted bypublication on a list by Scottish Ministers under section 50 of the Regulatory Reform Scotland Act 2014 In Northern Ireland appliances are exempted by publication on a list by the Department of Agriculture Environment and Rural Affairs under Section 16 of the Environmental Better regulation Act Northern Ireland 2016 In Wales appliances are exempted by regulations made by...

Страница 13: ...D CENTRE STAND a b c d e 697 647 103 76 532 697 647 103 76 532 824 774 230 203 659 944 894 350 323 779 944 894 350 323 779 b c d e a FRONT VIEW SIDE VIEW BACK VIEW TOP VIEW 96 162 403 418 152 159 567 520 600 Optional vertical rear flue adaptor Optional external air manifold kit charnwood ...

Страница 14: ...IONS mm 1130 980 110 115 844 1130 980 110 115 844 1200 1150 280 285 1014 1330 1280 410 415 1144 1330 1280 410 415 1144 b c d e a a b c d e 179 191 441 178 619 439 585 113 660 Optional vertical rear flue adaptor FRONT VIEW SIDE VIEW BACK VIEW TOP VIEW Optional external air manifold kit charnwood ...

Страница 15: ... Door Catch 26 010 ST031 Door Catch Spacer 27 008 FFW015 M12 Double Coil Spring Washer 28 008 PX95 Door Riddling Ashpan Tool 29 008 BW39 S Hinge Pin Set 30 002 PY24 Hinge Post 31 004 PY25B Hinge Post Shim 0 9mm 32 004 PY25A Hinge Post Shim 2mm 33 008 AY37 Air Control Knob Item Part No Description 34 004 CY22S Secondary Air Inlet Flap 35 004 CY21 Air Bypass Slide 36 004 CY22P Primary Air Inlet Flap...

Страница 16: ...002 PX92 Door Knob Spindle 23 008 FFN001 M12 Half Nut 24 004 ST008 Tabbed Locking Washer 25 002 AY14 Door Catch Cam 26 010 ST031 Door Catch Spacer 27 008 FFW015 M12 Double Coil Spring Washer 28 008 PX95 Door Riddling Ashpan Tool 29 008 PV28 S Hinge Pin Set 2 Per Set 30 004 GV24 Rear Brick Joining Bracket 31 002 RY26 Hinge Post 32 004 RY25B Hinge Post Shim 0 9mm 33 004 RY25A Hinge Post Shim 2mm 34 ...

Страница 17: ...015 RXE44 CPD 2015 Fuel type WOOD LOGS WOOD LOGS Emission of CO in combustion products 0 10 0 10 Mean flue gas temperature 336 C 330 C Flue spigot temperature 403 C 396 C Space heating thermal output 8kW 12kW Energy efficiency 77 80 Minimum distance to combustible materials Side Rear 450mm 600mm 500mm 500mm Particles mg m ⁿ 15 14 Fulfilled requirements BStV of the City of Munich and the City of Re...

Страница 18: ......

Страница 19: ... e g i s t e r e d i n E n g l a n d N o 0 3 8 0 9 3 7 1 charnwood BISHOPS WAY NEWPORT ISLE OF WIGHT PO30 5WS UNITED KINGDOM T 4 4 0 19 8 3 5 3 7 7 7 7 F 4 4 0 19 8 3 5 3 7 7 8 8 C O N TA C T U S AT W W W C H A R N W O O D C O M y o u r p re m i e r d e a l e r ...

Отзывы: