TROUBLESHOOTING SUGGESTIONS
12
SYMPTOM
POSSIBLE CAUSE
SUGGESTED REMEDY
Water won’t heat
Tank heater switch OFF
Press switch to ON
Brewer unplugged or circuit
breaker tripped
Check power supply cord
Check / reset circuit breaker
Temperature setpoint too low
Set for desired temperature
Hi-Limit safety switch tripped
Allow to cool hi-limit will self-reset
Damaged internal component or
wiring
Examine wiring & connectors,
controller, water level probe and
heating element
Repair/replace as needed
Coffee level too high or low
Brew select keys not properly
programmed
Program brew select keys
See page 8
No brew plus no flow from hot
water faucet
Water supply OFF
Turn water supply ON
Solenoid inlet strainer plugged
Clean strainer
Water filter (if used) plugged
Replace filter element
Damaged internal component or
wiring
Check wiring & connectors, inlet
solenoid, controller and water
level probe
Brew nozzle plugged
Disassemble and clean lower pod
holder.
Damaged internal component or
wiring
Check wiring & connectors, pump
and brew valve
No flow from hot water faucet
(brew OK)
Damaged internal component or
wiring
Check wiring & connectors,
faucet valve and dispense switch
Pod not dried at end of brew
Vent hose kinked
Check/repair vent hose
Poor coffee quality
Keep brewer and cups clean.
Install optional taste and odor filter, and replace cartridges regularly.
Use a fresh quality pod with a consistent roast for each brew.
No brew (faucet flows OK)
Tea brew is too strong or weak
Brew select keys not properly
programmed for dilution
Program brew select keys
See page 8