background image

SERVICING INSTRUCTIONS (continued) 

19 

CAUTION:  

CHEMICAL BURN 
HAZARD

 

Deliming chemicals may be 
caustic.  Wear appropriate     
protective gloves and goggles 
during this procedure. 
Never siphon deliming      
chemicals or solutions by 
mouth. 
This operation should only be 
performed by qualified and    
experienced service personnel. 
 
 

IMPORTANT: 

 DO NOT spill, 

splash or pour water or deliming 
solution into or over any internal 
component other than the inside 
of the water tank. 
 
 

IMPORTANT: 

 DO NOT allow 

any internal components to 
come into contact with the     
deliming solution.  Take care to 
keep all internal components 
dry. 
 
 

NOTE:

  Repeat steps 4 thru 5 

as required to remove all scale 
and lime build-up. 
 
 

NOTE: 

 Normally, silicone 

hoses do not need to be        
delimed.  Should deliming 
hoses become necessary, 
Bloomfield recommends        
replacing the hoses. 

PROCEDURE:  Delime the Water Tank  

 
PRECAUTIONS:     Disconnect brewer from electric power.  
                                Allow brewer to cool. 

 
FREQUENCY:        As required (Brewer slow to heat) 

 
TOOLS:                   Deliming Solution 
                                Protective Gloves, Goggles & Apron 
                                Mild Detergent, Clean Soft Cloth or Sponge 
                                Bristle Brush, Bottle Brush 
                                Large Sink (or other appropriate work area) 

 

1.    Disconnect brewer from electric power.  Turn off the water 
       shut-off valve and disconnect the water supply line from the 
       brewer inlet fitting. 

 
2.    Remove the tank lid assembly as described on page 15. 

 
3.

Remove the water tank from the brewer body by lifting 
straight up.  Empty all water from the tank.  Set the tank back 
into the brewer. 

 
4.    Mix 2 quarts of deliming solution according to the            
       manufacturer’s directions.  Carefully pour the deliming 
       solution into the water tank.  Lower the lid assembly back       
       onto the tank.  Allow to sit for 30 minutes, or as directed by 
       the  manufacturer. 

 
5.    At end of soaking period, remove lid assembly from tank.  
       Thoroughly rinse internal components of lid assembly with 
       clear water.  Using a stiff bristle brush, scrub the heating    
       element (and faucet water coil on automatic brewers) to            
       remove lime and calcium build-up.  Rinse with clean water.  
       Store lid assembly in a safe location . 

 
6.    Remove the tank from the brewer and empty.  Using a stiff 
       bristle brush, scrub the interior of the water  tank to remove 
       lime and calcium build-up.  Rinse with clean water.  
7.    Set the tank back into the brewer.  Reassemble the tank lid to 
       the water tank.  Make sure the gasket is properly in place, 
       then reinstall the hold-down strap. 

 
8.    Reinstall wiring to heating element and thermostat.  Reinstall 
       the hi-limit thermostat (if removed).  For automatic brewers, 
       reassemble piping for the faucet.  Verify that all internal    
       components are dry, then reinstall the top panel. 

 
10. Reconnect brewer to electrical supply and, for automatic 

brewers, reconnect water supply. 

 
11. Run at least ten full brew cycles without pods, and discard 
       all water generated. 

 
12. Brewer is ready to use. 

Содержание 9600 Single Cup

Страница 1: ...TED IN CHINA 687 p n 77195 Rev ECN12792 M687 050207 cps Model 9600 Single Cup Brewer OWNERS MANUAL For COFFEE BREWERS MODELS 9600 SINGLE CUP INCLUDES Installation Operation Use Care Servicing Instruct...

Страница 2: ...ffee carry a 90 days parts warranty only excludes decanters THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTA...

Страница 3: ...s the information needed to properly install this appliance and to use care for and maintain or repair the appliance in a manner which will ensure its optimum performance WARRANTY STATEMENT xi SPECIFI...

Страница 4: ...FEATURES AND OPERATING CONTROLS AUTOMATIC BREWERS 2 Fig 1 Features Operating Controls for Single Cup Brewers...

Страница 5: ...oducts for human consumption No other use is recommended or authorized by the manufacturer or its agents This appliance is intended for use in commercial establishments where all operators are familia...

Страница 6: ...the counter to prevent tipping IMPORTANT To enable the installer to make a quality installation and to minimize installation time the following suggestions and tests should be done before the actual u...

Страница 7: ...that must use a saddle tap shut off the main water supply and drill a 3 16 minimum tap for the saddle connection in order to insure an ample water supply Remember to flush the line prior to installin...

Страница 8: ...d to protect you from electrical shock in the event of internal damage Never cut off the ground prong nor twist a blade to fit an existing receptacle Contact a licensed electrician to install the prop...

Страница 9: ...illing When solenoid closes tank is full 2 Place an empty container on the cup grid Press the HOT WATER DISPENSE BUTTON and dispense one cup of water Tank should refill Discard water 3 Press TANK HEAT...

Страница 10: ...beep sounds to enter the setting into memory OR For PULSE BREW a Press and release the key to start the water flow b Press and release the key again to stop the flow after the time desired for the fir...

Страница 11: ...od holder by pulling the LOCKING LEVER fully forward 2 Pull the BREW TRAY fully forward This will automatically eject the used pod 3 Slide the tray fully to the rear In order to prevent an unintended...

Страница 12: ...cloth moistened with clean water 6 Wash the pod drawer drip tray and cup grid in a sink using warm water and a mild detergent Rinse with clean water and allow to air dry 7 Wipe the exterior of the bre...

Страница 13: ...OCKING LEVER fully forward 9 Pull the BREW TRAY fully forward to eject the sanitizer packet then slide it fully to the rear Gently pull the LOCKING LEVER DOWN then push it fully to the rear to lock th...

Страница 14: ...Solenoid inlet strainer plugged Clean strainer Water filter if used plugged Replace filter element Damaged internal component or wiring Check wiring connectors inlet solenoid controller and water lev...

Страница 15: ...NEL Remove top panel to access hot water tank thermostat heating elements brew pump and tubing brew solenoid hot water dispenser solenoid and piping pod holders and brew tray Top panel is held by scre...

Страница 16: ...e to be performed by qualified technical personnel only NOTE Optimum brewing temperature range is 195 F to 205 F 90 C to 96 C IMPORTANT A mechanical thermostat will maintain temperature within 5 F To...

Страница 17: ...t all wiring from heating element Remove tank ground wire Loosen nuts and center screw on tank hold down strap Remove hold down strap by sliding short slotted end off of locking stud and lifting it of...

Страница 18: ...om turning while installing or removing the inlet water supply flare nut Remove fill tubing Disconnect wiring Remove two screws holding solenoid to access door Reassemble in reverse order CLEAN SOLENO...

Страница 19: ...retaining screw and elbow fitting Be sure elbow fitting o ring and ring plate o ring are properly reinstalled after cleaning Clean all components using mild detergent and clean water Rinse with clean...

Страница 20: ...orientation REPLACE CONTROLLER Disconnect brewer from electric power Remove top panel Note location of wire connections Be sure to mark the two keypad ribbon cables as to orientation Disconnect wirin...

Страница 21: ...id assembly as described on page 15 3 Remove the water tank from the brewer body by lifting straight up Empty all water from the tank Set the tank back into the brewer 4 Mix 2 quarts of deliming solut...

Страница 22: ...EXPLODED VIEW PARTS LIST 20 CABINET COMPONENTS...

Страница 23: ...VENT TUBE LONG 1 20 8043 83 HI LIMIT THERMOSTAT 1 21 87172 TUBE FILL 1 22 83521 PROBE WATER LEVEL 1 23 82390 GROMMET 3 8 1 24 83532 SLEEVE PROBE 1 ITEM PART NO DESCRIPTION QTY 25 86968 TANK COVER 1 2...

Страница 24: ...EXPLODED VIEW PARTS LIST 22 BREW TRAY COMPONENTS...

Страница 25: ...SWING ARM LEFT 1 70 86851 SWING ARM RIGHT 1 71 86980 COTTER PIN 06Dx 5 SS 2 72 86977 PIVOT ROD 1 73 86974 BEARING THRUST 2 74 SPRING 1 75 86970 O RING 2 039 1 ITEM PART NO DESCRIPTION QTY 76 86846 RI...

Страница 26: ...EXPLODED VIEW PARTS LIST continued 24 SERVICE PARTS KITS 84427 VALVE ASSEMBLY COMPLETE 85218 INLET FITTING KIT Includes cap fitting gasket strainer 85219 INLET STRAINER...

Страница 27: ...25 WIRING DIAGRAM...

Страница 28: ...n of Carrier Commercial Refrigeration In US and Canada Telephone 775 689 5700 Fax 888 492 2783 Fax 800 356 5142 website www wellsbloomfield com for orders only Bloomfield Industries proudly supports C...