background image

PRECAUTIONS AND GENERAL INFORMATION 

WARNING:  

ELECTRIC SHOCK HAZARD 

All servicing requiring access to non-insulated components must be performed by qualified 
service personnel.  Do not open any access panels which require the use of tools. 

              Failure to heed this warning can result in electrical shock. 

 

WARNING:  

INJURY HAZARD 

All installation procedures must be performed by qualified personnel with full knowledge of all 
applicable electrical and plumbing codes.  Failure could result in property damage and 
personal injury. 

 

WARNING:  

ELECTRIC SHOCK HAZARD 

Brewer must be properly grounded to prevent possible shock hazard.  DO NOT assume a 
plumbing line will provide such a ground.  Electrical shock will cause death or serious Injury. 

 

WARNING:  

BURN HAZARD 

This appliance dispenses very hot liquid.  Serious bodily injury from scalding can occur from 
contact with dispensed liquids. 

This appliance is intended for commercial use only. 

 
This appliance is intended for use to brew beverage products for 
human consumption.  No other use is recommended or  
authorized by the manufacturer or its agents. 

 
This appliance is intended for use in commercial establishments, 
where all operators are familiar with the appliance use,  
limitations and associated hazards.  Operating instructions and 
warnings must be read and understood by all operators and  
users. 

 

 
The following trouble shooting, component views and parts lists 
are included for general reference, and are intended for use by 
qualified service personnel. 

 
This manual should be considered a permanent part of this 
appliance.  The manual must remain with the appliance if it is 
sold or moved to another location. 
 
 
 
 
 
 
This brewer is         and           listed under UL file E9253. 
 
 
 
This brewer meets 

      

 Standard 4 only when installed,        

operated and maintained in accordance with the enclosed        
instructions. 

AGENCY LISTING INFORMATION 

CAUTION:  

 

ELECTRICAL DAMAGE 

 

DO NOT plug in or energize this 
appliance until all 

Installation     

Instructions 

are read and followed.  

Damage to the Brewer will occur if 
these instructions are not followed. 

 

CAUTION:   

BURN HAZARD  

 

Exposed surfaces of the            
appliance may be HOT to the 
touch, and can cause serious 
burns. 

E9253

STD 4

E9253

Содержание 9600 Single Cup

Страница 1: ...TED IN CHINA 687 p n 77195 Rev ECN12792 M687 050207 cps Model 9600 Single Cup Brewer OWNERS MANUAL For COFFEE BREWERS MODELS 9600 SINGLE CUP INCLUDES Installation Operation Use Care Servicing Instruct...

Страница 2: ...ffee carry a 90 days parts warranty only excludes decanters THE FOREGOING OBLIGATION IS EXPRESSLY GIVEN IN LIEU OF ANY OTHER WARRANTIES EXPRESSED OR IMPLIED INCLUDING ANY IMPLIED WARRANTY OF MERCHANTA...

Страница 3: ...s the information needed to properly install this appliance and to use care for and maintain or repair the appliance in a manner which will ensure its optimum performance WARRANTY STATEMENT xi SPECIFI...

Страница 4: ...FEATURES AND OPERATING CONTROLS AUTOMATIC BREWERS 2 Fig 1 Features Operating Controls for Single Cup Brewers...

Страница 5: ...oducts for human consumption No other use is recommended or authorized by the manufacturer or its agents This appliance is intended for use in commercial establishments where all operators are familia...

Страница 6: ...the counter to prevent tipping IMPORTANT To enable the installer to make a quality installation and to minimize installation time the following suggestions and tests should be done before the actual u...

Страница 7: ...that must use a saddle tap shut off the main water supply and drill a 3 16 minimum tap for the saddle connection in order to insure an ample water supply Remember to flush the line prior to installin...

Страница 8: ...d to protect you from electrical shock in the event of internal damage Never cut off the ground prong nor twist a blade to fit an existing receptacle Contact a licensed electrician to install the prop...

Страница 9: ...illing When solenoid closes tank is full 2 Place an empty container on the cup grid Press the HOT WATER DISPENSE BUTTON and dispense one cup of water Tank should refill Discard water 3 Press TANK HEAT...

Страница 10: ...beep sounds to enter the setting into memory OR For PULSE BREW a Press and release the key to start the water flow b Press and release the key again to stop the flow after the time desired for the fir...

Страница 11: ...od holder by pulling the LOCKING LEVER fully forward 2 Pull the BREW TRAY fully forward This will automatically eject the used pod 3 Slide the tray fully to the rear In order to prevent an unintended...

Страница 12: ...cloth moistened with clean water 6 Wash the pod drawer drip tray and cup grid in a sink using warm water and a mild detergent Rinse with clean water and allow to air dry 7 Wipe the exterior of the bre...

Страница 13: ...OCKING LEVER fully forward 9 Pull the BREW TRAY fully forward to eject the sanitizer packet then slide it fully to the rear Gently pull the LOCKING LEVER DOWN then push it fully to the rear to lock th...

Страница 14: ...Solenoid inlet strainer plugged Clean strainer Water filter if used plugged Replace filter element Damaged internal component or wiring Check wiring connectors inlet solenoid controller and water lev...

Страница 15: ...NEL Remove top panel to access hot water tank thermostat heating elements brew pump and tubing brew solenoid hot water dispenser solenoid and piping pod holders and brew tray Top panel is held by scre...

Страница 16: ...e to be performed by qualified technical personnel only NOTE Optimum brewing temperature range is 195 F to 205 F 90 C to 96 C IMPORTANT A mechanical thermostat will maintain temperature within 5 F To...

Страница 17: ...t all wiring from heating element Remove tank ground wire Loosen nuts and center screw on tank hold down strap Remove hold down strap by sliding short slotted end off of locking stud and lifting it of...

Страница 18: ...om turning while installing or removing the inlet water supply flare nut Remove fill tubing Disconnect wiring Remove two screws holding solenoid to access door Reassemble in reverse order CLEAN SOLENO...

Страница 19: ...retaining screw and elbow fitting Be sure elbow fitting o ring and ring plate o ring are properly reinstalled after cleaning Clean all components using mild detergent and clean water Rinse with clean...

Страница 20: ...orientation REPLACE CONTROLLER Disconnect brewer from electric power Remove top panel Note location of wire connections Be sure to mark the two keypad ribbon cables as to orientation Disconnect wirin...

Страница 21: ...id assembly as described on page 15 3 Remove the water tank from the brewer body by lifting straight up Empty all water from the tank Set the tank back into the brewer 4 Mix 2 quarts of deliming solut...

Страница 22: ...EXPLODED VIEW PARTS LIST 20 CABINET COMPONENTS...

Страница 23: ...VENT TUBE LONG 1 20 8043 83 HI LIMIT THERMOSTAT 1 21 87172 TUBE FILL 1 22 83521 PROBE WATER LEVEL 1 23 82390 GROMMET 3 8 1 24 83532 SLEEVE PROBE 1 ITEM PART NO DESCRIPTION QTY 25 86968 TANK COVER 1 2...

Страница 24: ...EXPLODED VIEW PARTS LIST 22 BREW TRAY COMPONENTS...

Страница 25: ...SWING ARM LEFT 1 70 86851 SWING ARM RIGHT 1 71 86980 COTTER PIN 06Dx 5 SS 2 72 86977 PIVOT ROD 1 73 86974 BEARING THRUST 2 74 SPRING 1 75 86970 O RING 2 039 1 ITEM PART NO DESCRIPTION QTY 76 86846 RI...

Страница 26: ...EXPLODED VIEW PARTS LIST continued 24 SERVICE PARTS KITS 84427 VALVE ASSEMBLY COMPLETE 85218 INLET FITTING KIT Includes cap fitting gasket strainer 85219 INLET STRAINER...

Страница 27: ...25 WIRING DIAGRAM...

Страница 28: ...n of Carrier Commercial Refrigeration In US and Canada Telephone 775 689 5700 Fax 888 492 2783 Fax 800 356 5142 website www wellsbloomfield com for orders only Bloomfield Industries proudly supports C...