SERVICING INSTRUCTIONS (continued)
TEMPERATURE ADJUSTMENT
Unplug power cord or turn circuit breaker OFF. Remove top
panel. Remove button plug from front panel
Pull tank lid plug or vent tube out of tank lid and insert a
thermometer of known accuracy in hole. Reconnect brewer to
electrical power.
Place empty decanter under brew chamber. Energize brewer
and allow unit to heat. When HEAT light goes out, read the
temperature displayed on thermometer.
Adjust WATER TEMP dial on controller; clockwise increases
temperature. Refer to Table 1 below for proper brewing
temperature based on altitude.
Upon completion, remove thermometer and reinstall the plug or
vent tube.
Fig. 13 Checking and Adjusting Brew Temperature
CAUTION
Electric Shock
Hazard
These procedures involve
exposed electrical circuits.
These procedures are to be
performed by qualified
technical personnel only.
NOTE:
Optimum brewing
temperature is 200ºF (93.3ºC)
± 5ºF (±2.8C).
Thermostat must be adjusted so
that tank temperature does not
exceed 205ºF (96ºC).
IMPORTANT:
An electronic temperature
controller will maintain
temperature within ±2ºF.
To prevent boiling water in the
brewer, controller should be
adjusted to a maximum
temperature equal to the local
boiling temperature minus 2ºF,
or 205ºF, whichever is less.
Table 1 Boiling Temperature by Altitude