SERVICING INSTRUCTIONS
CAUTION
Electric Shock
Hazard
Opening access panels or
removing warmer plates on this
brew may expose uninsulated
electrical components.
Disconnect brewer from
electrical power before
removing any panel.
ACCESS PANELS
TOP PANEL:
Remove top panel to access hot water tank, thermo probe,
heating elements, brew circuit tubing, faucet valve and piping.
Top panel is held by two screws at the front and a retaining lip at
the rear.
FRONT PANEL:
Remove upper front panel to access controller, power board and
solenoid.
Upper front panel is held by two screws at the bottom and a
retaining lip at the top.
To remove lower front panel: Remove upper front panel,
unscrew warmer plate, then remove two retaining clips.
SOLENOID DOOR:
Remove solenoid door to access solenoid plumbing connections.
Solenoid door is held by two screws and a retaining lip.
WARMER PLATES:
Warmer plates unscrew counterclockwise.
Fig. 12 Access Panels
14