background image

Page 14

ProPAR 7.4 Manual Rev. A  

 

 

Copyright (c) 2012 Blizzard Lighting, LLC

5. APPENDIX

A Quick Lesson On DMX

DMX (aka DMX-512) was created in 1986 by the United States 

Institute for Theatre Technology (USITT) as a standardized 

method for connecting lighting consoles to lighting dimmer 

modules. It was revised in 1990 and again in 2000 to allow 

more flexibility.  The Entertainment Services and Technology 

Association (ESTA) has since assumed control over the DMX512 

standard.  It has also been approved and recognized for ANSI 

standard classification.  

DMX covers (and is an abbreviation for) Digital MultipleXed 

signals. It is the most common communications standard used 

by lighting and related stage equipment.  

DMX provides up to 512 control “channels” per data link. Each 

of these channels was originally intended to control lamp 

dimmer levels. You can think of it as 512 faders on a lighting 

console, connected to 512 light bulbs. Each slider’s position 

is sent over the data link as an 8-bit number having a value 

between 0 and 255. The value 0 corresponds to the light bulb 

being completely off while 255 corresponds to the light bulb 

being fully on. 

DMX data is transmitted at 250,000 bits per second using 

the RS-485 transmission standard over two wires. As with 

microphone cables, a grounded cable shield is used to prevent 

interference with other signals.

There are five pins on a DMX connector: a wire for ground 

(cable shield), two wires for “Primary” communication which 

goes from a DMX source to a DMX receiver, and two wires for 

a “Secondary” communication which goes from a DMX receiver 

back to a DMX source. Generally, the “Secondary” channel is 

not used so data flows only from sources to receivers.  Hence, 

most of us are most familiar with DMX-512 as being employer 

over typical 3-pin “mic cables,” although this does not conform 

to the defined standard.

Содержание ProPar Seven 4

Страница 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2012...

Страница 2: ...nt 7 Connecting A Bunch Of ProPar Seven 4 PAR Cans 7 Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9 Mount...

Страница 3: ...stat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Switch Not all fixtures have a voltage select switch so please verify th...

Страница 4: ...re servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operat...

Страница 5: ...unting yoke allows flexibility in positioning Aluminum die casting housing OPTICAL Installed optics 25 40 available 4 140 Lux 1m 1 290 Lux 2m full white 400hz flicker free LED drivers Light Source 7 3...

Страница 6: ...Lighting LLC Figure 1 The ProPar Seven 4 Pin Up Picture High Power Quad Color LEDs Powder coated Cast Aluminum Enclosure Dual Mounting Brackets Figure 2 The Rear Connections Sound Sensitivity Knob Mi...

Страница 7: ...Fixtures on a serial data link must be daisy chained in one single line Also connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result i...

Страница 8: ...d like to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used N...

Страница 9: ...the Operating Adjustments section in this manual for complete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there is...

Страница 10: ...OWN Scrolls through menu items and numbers in descending order ENTER Is used to select and confirm store the current selection The Control Panel LED Display shows the menu items you select from the me...

Страница 11: ...D CO 2 Static GREEN CO 3 Static BLUE CO 4 Static WHITE CO 5 Static YELLOW CO 6 Static MAGENTA CO 7 Static SALMON CO 8 Static CYAN CO 9 Static MINT CO10 Static ICE BLUE C011 Static PALE PINK C012 Stati...

Страница 12: ...R Then use the UP DOWN buttons to select AUTO and press ENTER You will then be prompted to select the chase speed by selecting from SP 1 slowest to SP 8 fastest Then hit ENTER to confirm 3 To use the...

Страница 13: ...Auto Shut Off Check the fan in the fixture If it is stopped or moving slower than normal the unit may have shut itself off due to high heat This is to protect the fixture from overheating Clear the f...

Страница 14: ...mmer levels You can think of it as 512 faders on a lighting console connected to 512 light bulbs Each slider s position is sent over the data link as an 8 bit number having a value between 0 and 255 T...

Страница 15: ...to 512 bytes of data Data packets are transmitted continuously As soon as one packet is finished another can begin with no delay if desired usually another follows within 1 ms If nothing is changing...

Страница 16: ...s satistfaction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sendi...

Страница 17: ...LEDs 100 000 hours Optical Beam Angle 25 degree optics standard Luminous Intensity Lux m Red Green Blue White 1m 960 475 660 1121 2m 300 152 213 290 Thermal Max Operating Temp 104 degrees F 40 degrees...

Страница 18: ...Page 18 ProPAR 7 4 Manual Rev A Copyright c 2012 Blizzard Lighting LLC This page intentionally left blank...

Страница 19: ...This page intentionally left blank...

Страница 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Отзывы: