1. GETTING STARTED

What’s In The Box?

 

• 1 x ProPar Seven.4™ Professional LED PAR Fixture

 

• A totally rockin’ DMX Cable

 

• This Lovely User Manual

Getting It Out Of The Box

Congratulations on purchasing one of the coolest LED Par fixtures 

anywhere!  Now that you’re the proud owner of a ProPar Seven.4™ (or 

hopefully, MORE!), you should carefully unpack the box and check the 

contents to ensure that all parts are present and in good condition. If 

anything looks as if it has been damaged in transit, notify the shipper 

immediately and keep the packing material for inspection.  Again, 

please save the carton and all packing materials. If a fixture must be 

returned to the factory, it is important that the fixture be returned in 

the original factory box and packing.

Powering Up!

All fixtures must be powered directly off a switched circuit and 

cannot 

be run off a rheostat (variable resistor) or dimmer circuit, even 

if the rheostat or dimmer channel is used solely for a 0% to 

100% switch

.  

AC Voltage Switch -

 Not all fixtures have a voltage select switch, so 

please verify that the fixture you receive is suitable for your local 

power supply.  See the label on the fixture or refer to the fixture’s 

specifications chart for more information.  A fixture’s listed current 

rating is its average current draw under normal conditions. Check 

the fixture or device carefully to make sure that if a voltage selection 

switch exists that it is set to the correct line voltage you will use.

Warning! 

Verify that the voltage select switch on your unit 

matches the line voltage applied. Damage to your fixture may 

result if the line voltage applied does not match the voltage 

indicated on the voltage selector switch. All fixtures must be 

connected to circuits with a suitable Ground (Earthing).

Getting A Hold Of Us

If something is wrong, just give us a call or send an email.  

We’ll be happy to help, honest.

 

Blizzard Lighting

W220 N1531 Jericho Ct. Ste E

Waukesha, WI 53186 USA

www.blizzardlighting.com

414-395-8365

Содержание ProPar Seven 4

Страница 1: ...Blizzard Lighting LLC www blizzardlighting com Waukesha WI USA Copyright c 2012...

Страница 2: ...nt 7 Connecting A Bunch Of ProPar Seven 4 PAR Cans 7 Data DMX Cables 7 Cable Connectors 8 3 Pin 5 Pin Huh 8 Take It To The Next Level Setting up DMX Control 8 Fixture Linking Master Slave Mode 9 Mount...

Страница 3: ...stat variable resistor or dimmer circuit even if the rheostat or dimmer channel is used solely for a 0 to 100 switch AC Voltage Switch Not all fixtures have a voltage select switch so please verify th...

Страница 4: ...re servicing or replacing fuse and be sure to replace with same fuse size and type ALWAYS secure fixture using a safety chain NEVER carry the fixture by its cord Use its carrying handles DO NOT operat...

Страница 5: ...unting yoke allows flexibility in positioning Aluminum die casting housing OPTICAL Installed optics 25 40 available 4 140 Lux 1m 1 290 Lux 2m full white 400hz flicker free LED drivers Light Source 7 3...

Страница 6: ...Lighting LLC Figure 1 The ProPar Seven 4 Pin Up Picture High Power Quad Color LEDs Powder coated Cast Aluminum Enclosure Dual Mounting Brackets Figure 2 The Rear Connections Sound Sensitivity Knob Mi...

Страница 7: ...Fixtures on a serial data link must be daisy chained in one single line Also connecting more than 32 fixtures on one serial data link without the use of a DMX optically isolated splitter may result i...

Страница 8: ...d like to build your own the chart below details a proper cable conversion Conductor 3 Pin Female Output 5 Pin Male Input Ground Shield Pin 1 Pin 1 DMX Data Pin 2 Pin 2 DMX Data Pin 3 Pin 3 Not Used N...

Страница 9: ...the Operating Adjustments section in this manual for complete instructions for this type of setup and configuration Mounting Rigging This fixture may be mounted in any SAFE position provided there is...

Страница 10: ...OWN Scrolls through menu items and numbers in descending order ENTER Is used to select and confirm store the current selection The Control Panel LED Display shows the menu items you select from the me...

Страница 11: ...D CO 2 Static GREEN CO 3 Static BLUE CO 4 Static WHITE CO 5 Static YELLOW CO 6 Static MAGENTA CO 7 Static SALMON CO 8 Static CYAN CO 9 Static MINT CO10 Static ICE BLUE C011 Static PALE PINK C012 Stati...

Страница 12: ...R Then use the UP DOWN buttons to select AUTO and press ENTER You will then be prompted to select the chase speed by selecting from SP 1 slowest to SP 8 fastest Then hit ENTER to confirm 3 To use the...

Страница 13: ...Auto Shut Off Check the fan in the fixture If it is stopped or moving slower than normal the unit may have shut itself off due to high heat This is to protect the fixture from overheating Clear the f...

Страница 14: ...mmer levels You can think of it as 512 faders on a lighting console connected to 512 light bulbs Each slider s position is sent over the data link as an 8 bit number having a value between 0 and 255 T...

Страница 15: ...to 512 bytes of data Data packets are transmitted continuously As soon as one packet is finished another can begin with no delay if desired usually another follows within 1 ms If nothing is changing...

Страница 16: ...s satistfaction and wow factor That s what it s all about after all Returns Gasp We ve taken a lot of precautions to make sure you never even have to worry about sending a defective unit back or sendi...

Страница 17: ...LEDs 100 000 hours Optical Beam Angle 25 degree optics standard Luminous Intensity Lux m Red Green Blue White 1m 960 475 660 1121 2m 300 152 213 290 Thermal Max Operating Temp 104 degrees F 40 degrees...

Страница 18: ...Page 18 ProPAR 7 4 Manual Rev A Copyright c 2012 Blizzard Lighting LLC This page intentionally left blank...

Страница 19: ...This page intentionally left blank...

Страница 20: ...Enjoy your product Our sincerest thanks for your purchase The team Blizzard Lighting...

Отзывы: