Compressor maintenance 6
19
6.1.1
Oil change
Read all the information provided in
Section 6.1
before proceeding with any maintenance jobs.
Change the oil following the initial
500 hours
of use and then every
2500 hours
and in event once a year.
In case of not frequently use (few hours of duty per day) you should change the oil every 6 months.
Open the shroud
Unscrew the cap
1
situated at the base of the
screw unit.
Screw an attachment with tail piece 2 (supplied with
the compressor).
Open tap
3
.
Once emptied, shut-off tap
3
and remove the
attachment with tail piece.
Fill-up with oil to the half of the union 4,
then screw cap 1 back in place and close-
up the compressor again.
Once the oil and oil filter have been changed
leave the compressor to run for roughly 5
minutes then turn it off and check the oil level
again. Add oil if necessary.
Check the oil level once a month.
1
2
3
Содержание MONSUN Fast R
Страница 1: ...Operating instructions MONSUN Fast R Screw Compressors Type Serial number Date 121455 01 2015 ...
Страница 29: ...7 Drowing and diagrams 28 7 2 Pneumatic diagrams ...
Страница 30: ...Drowing and diagrams 7 29 Maintenance program Model Serial Date Intervention Hours of duty Operator sign ...
Страница 31: ...7 Drowings and diagrams 30 Maintenance program Model Serial Date Intervention Hours of duty Operator sign ...