THREE-PHASE VERSION:
The thermal relay F1 (1) is setting as following:
Power
Nominal rate
kW / HP
380/415V
220/240V
2,2 / 3
6,7 A
11,5 A
DISCONNECT THE ELECTRICAL POWER SUPPLY FORM THE COMPRESSOR BEFORE
OPENING THE ELECTRICAL CABINET.
USEFUL TIPS FOR CORRECT COMPRESSOR PERFORMANCE
For the correct operational performance of the machine under full continuous load at the maximum working pressure,
ensure that the temperature of the work area in a closed room does not exceed +45°C. It is advisable to use the
compressor with a maximum service of 80% in one hour under full load in order to ensure the correct efficiency of the
product in time.
5.5
Stopping the compressor
Press the
STOP
button on the control panel (see par. 5.2) the compressor fail immediately.
Note!
By disconnecting the power supply from the external switch the compressor is completely
without power.