Communication Requirements
SemaConnect EV charging stations require cellular connectivity to function properly. To enable cellular connectivity, please
reference the following cellular carriers and minimum operational signal requirement at each SemaConnect EV charging
station location:
Verizon
4G LTE
Band 13
RSRP: -95 dBm
RSRQ: -13 dB
Band 4
ATT
4G LTE
Band 2
Band 4
Band 5
Band 12
Band 13
RSRP: -95 dBm
RSRQ: -13 dB
SemaConnect stations do not use 5G cellular or Wi-Fi communication protocols.
Network Platform Requirements
To enable modified output configurations or load management configurations, SemaConnect must be notified during
station Start-up/enrollment. Failure to do so may result in nuisance breaker tripping and/or system damage. Refer to Start
Up section of this manual for details
.