44
Charge on.
Figure 5-4. Place the Charging Plug into the Charger Holster.
5.3.1 Interrupt Charging
Please refer to STOP CHARGING section for more information.
5.3.2 Auto Restart
When a charging session is interrupted due to a temporary error condition, the Blink Charger will automatically
restart charging when the cause of the temporary error condition returns to normal. Status indicator lights remain
flashing RED until the error condition is resolved.
• Temporary error conditions include: Over Current, Over Voltage, Under Voltage, Over Temperature.
• For Over Current conditions: The charging seesion will be stop while OC occurs. After recovery from OC
for 30 seconds, Blink Charger will automatically restart charging for three times.
• When charging session stopped due to CCID trip, Blink Charger will try to restart after 15 minutes for 3
times.
5.3.3 Power Outage Recovery
When power resumes after an outage, the Blink Charger restarts automatically with a delay ranging from 120 to
720 seconds. The delay is designed to avoid impacting the utility grid when multiple chargers are in the same area
attempting to resume charging simultaneously.