Via Montefeltro, 6 – 20156 Milano (MI) – Italy
- 6 -
Tel. +39 (02) 3088583 – Fax +39 (02) 33406697
www.blinkmarine.com
–
PKP-2300-SI-FR_CANopenUM_REV1.3
6.
Reset CANopen node
Identifier
00h
Byte 0
81h
Reset CANopen node
Byte 1
XXh
Keypad CAN ID
00h: reset all the keypads
15h: reset the keypad with CAN ID =
15h.
Byte 2, 7
00h
Not used
Example:
Direction
Identifier
Format
Message
To Keypad
0
Std
81 15
7.
Stop CANopen node
Identifier
00h
Byte 0
XXh
02h: Stop CANopen node
00h: Stop CANopen node
(old PKP sw compatibility)
Byte 1
YYh
Keypad CAN ID
00h: stop all the keypads
15h: stop the keypad with CAN ID = 15h.
Byte 2, 7
00h
Not used
Example:
Direction
Identifier
Format
Message
To Keypad
0
Std
02 15
8.
Boot-up service
This service is used to signal that a NMT slave has entered the NMT state Pre-operational.
Identifier
700h + current CAN ID
Default 715h
Byte 0
00h
One data byte is transmitted with value 0.
Example:
Direction
Identifier
Format
Message
From Keypad
715h
Std
00h
The keypad with CAN ID 15h has entered the NMT state Pre-operational.