Via Montefeltro, 6 – 20156 Milano (MI) – Italy
- 9 -
Tel. +39 (02) 3088583 – Fax +39 (02) 33406697
www.blinkmarine.com
–
PKP-2200-SI_J1939_UM_REV1.0
Direction
Identifier
Format Message
Data
To Keypad
18EF2100h Ext
04 1B 6F 02 FF FF FF FF Set baud rate = 500kbit/s
14.
Set Source Address (70h)
This message is used to change the keypad CAN Source Address and/or the Keypad Identifier.
Either or both the Source Address or Keypad Identifier may be changed independently.
Connecting only one keypad to the bus when changing the keypad address is recommended. If
an invalid value is chosen, then no change is done to the stored value.
Byte 0
04h
Header bytes
Byte 1
1Bh
Byte 2
70h
Set Address message
Byte 3
XXh
XX: CAN Source Address
From 01h to FEh
FFh No change
Byte 4
YYh
YY: Keypad Identifier
From 00h to FEh
FFh No change
Byte 5,7
FFh
Not used
Example:
Direction
Identifier
Format Message
Data
To
Keypad
18EF2100h Ext
04 1B 70 18 22 FF FF
FF
Set Source address =
18h,
Set Keypad identifier =
22h.
15.
Periodic state transmission (71h)
This message enables or disables the periodic transmission of the Key state.
When enabled, one contact state message is periodically sent for each button of the keypad.
For some keypad models there could be additional messages (e.g. the PKP2400 has 8 buttons
but 11 messages are sent).
The period is set to 100ms as default value but can be changed by command 77h.
Byte 0
04h
Header bytes
Byte 1
1Bh
Byte 2
71h
Periodic state transmission message
Byte 3
XXh
XX:
00h Disabled (default)
01h Enabled
Byte 4,7
FFh
Not used
Example:
Direction
Identifier
Format Message
Data
To Keypad
18EF2100h Ext
04 1B 71 01 FF FF FF
FF
Enable periodic
state transmission.