Страница 3: ...mming Mode 4 Programming Methods 5 Feature Select Programming 5 Decimal Programming 5 Module Broadcast 5 Memory Key 6 Download Contents of Memory Key to Keypad 6 Copy the Keypad Contents to the Memory...

Страница 4: ...Zone Closure 11 Beep on Trouble 12 Keypad Tamper Enable 12 Combus Voltmeter 13 Programmable Output Options 14 PGM State 14 PGM Deactivation Mode 14 PGM Base Time 15 PGM Override 15 PGM Timer 15 PGM Ac...

Страница 5: ...ton Since all programming is accomplished through the keypad please read this manual carefully 1 1 Specifications Power input 12 to 16 Vdc 80mA maximum PGM current limit 50 mA Number of inputs 1 Power...

Страница 6: ...ypad has one traditional hardwired input terminal allowing you to connect one detector or door contact directly to the keypad For example a door contact located at the entry point of an establishment...

Страница 7: ...o any device connected to it If the current drawn is to exceed the current limit a relay should be connected to the PGM as shown in Figure 2 1 Figure 2 1 Connecting the Keypad and Keypad Zone The keyp...

Страница 8: ...er to the WinLoad instructions or visit our website at www paradox ca 3 1 Entering Module Programming Mode The keypad like all other modules in the system is programmed through the control panel To do...

Страница 9: ...y again to remove the digit from the display thereby disabling the option Press ENTER when options are set 3 2 2 Decimal Programming Some sections require that a decimal value be entered In this metho...

Страница 10: ...function with the LCD keypad 3 5 Download Contents of Memory Key to Keypad Section 510 1 Insert the memory key into the keypad s connector labelled KEY refer to Figure 2 1 on page 3 2 To download the...

Страница 11: ...ite protect jumper is ON refer to Figure 3 1 2 To copy the contents to the memory key enter the keypad s programming mode and enter section 520 3 After the confirmation beep wait 5 seconds and remove...

Страница 12: ...d is connected to a DGP NE96 control panel 4 2 Display Access Code Entry Section 003 Option 1 The digits of the user access codes can be displayed on the LCD screen when they are entered 4 3 Display E...

Страница 13: ...tered The period of time in which no action is performed is defined by the Confidential Mode Timer 005 255 seconds refer to section 4 6 on page 10 Confidential Mode is activated by enabling option 4 O...

Страница 14: ...mer can be set from 005 seconds to 255 seconds Default 120 seconds 4 7 Time Display Option Section 003 Option 8 The LCD keypad comes with a time display option that can display the date as year month...

Страница 15: ...before the area is armed 4 10 Chime on Zone Closure Section 004 Option 4 During the Chime Zone Time Period that the user sets the keypad can emit an intermittent beep whenever a zone with the Chime fe...

Страница 16: ...beep will be re initialized whenever the trouble condition re occurs 4 12 Keypad Tamper Enable Section 006 Option 5 When tamper is enabled and the keypad s on board anti tamper switch is triggered the...

Страница 17: ...ge is too low This may occur when too many modules are connected to the bus a module is installed too far from the panel or if the system is running on the battery In some cases adding an external pow...

Страница 18: ...GM Activation Event occurs see section 5 6 the PGM will switch to its opposite state i e open to closed or closed to open The PGM can provide 50mA to any device connected to it 5 2 PGM Deactivation Mo...

Страница 19: ...its normal state until the PGM Override is disabled This option may be used to test the PGM connections 5 5 PGM Timer Section 008 If the keypad s on board PGM is in PGM Timed Mode the value programmed...

Страница 20: ...ired data 5 7 PGM Deactivation Event Sections 013 to 016 If the PGM Deactivation Option section 5 2 on page 14 is set to follow the PGM Deactivation event the PGM will return to its normal state when...

Страница 21: ...be programmed directly into the DGP NE96 control panel Refer to the DGP NE96 Reference Installation Manual and to the DGP NE96 Programming Guide for more details After entering the section correspondi...

Страница 22: ...current cursor position ARM Delete Until the End Pressing the ARM key will delete all characters and spaces to the right of the cursor and at the cursor s position DISARM Numeric Keys Alphanumeric Ke...

Страница 23: ...y is pressed it will toggle the case setting from lower to upper case and vice versa MEM Special Characters After pressing the MEM key the cursor will turn into a flashing black square Using Table 6 2...