180.OM.CL26.FS.IPI E v1.02
September 6, 2017
Page 4
Clarity 26 FS IPI
SAFETY PRECAUTIONS cont.
YOUR SAFETY
• Have the venting system inspected annually by a qualifi ed installer for blockage and signs of deterioration.
• To prevent injury, do not allow anyone who is unfamiliar with the stove to operate it.
• To prevent injury, if the pilot or pilot and burners have gone out on their own, open the glass door and wait 5
minutes to air out before attempting to relight the stove.
• Always keep the area around these appliances clear of combustible material, gasoline and other fl ammable
liquids and vapors.
• These appliances should not be used as a drying rack for clothing or for hanging Christmas stockings/
decorations.
• Due to the paint curing on the stove, a faint odor and slight smoking will likely be noticed when the stove is
fi rst used. Open a window until the smoking stops.
• Do not use this appliance if any part has been under water. Immediately call a qualifi ed service technician
to inspect the appliance and to replace any part of the control system and any gas control which has been
under water.
• Do not abuse the glass by striking it or slamming the door shut.
INSTALLATION
• Installation and service must be performed by a qualifi ed installer, service agency or gas supplier
• Only doors certifi ed with the appliance shall be used. (see door part numbers in “PARTS LIST”)
• This installation must conform to local codes or, in the absence of local codes, with the National Fuel Gas
Code, ANSI Z223.1 / NFPA 54 in the US, or the Natural Gas and Propane Installation Code, CSA B149.1 in
Canada.
• A manufactured home (USA only) or mobile home OEM installation must conform with the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a standard is not
applicable, the Standard for Manufactured Home Installations, ANSI / NCSBCS A225.1, or Standard for Gas
Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4.
• Always connect this gas appliance to a vent system and vent to the outside of the building envelope. Never
vent to another room or inside the building. Make sure the specifi ed vent pipe is used, properly sized and of
adequate height to provide suffi cient draft.
• The fl ow of combustion and ventilation air must not be obstructed .
• The appliance and its appliance main gas valve must be disconnected from the gas supply piping system
during any pressure testing of that system at test pressures in excess of 1/2 psi (3.5 kPa).
• This gas appliance must not be connected to a chimney fl ue serving a separate solid-fuel burning appliance.
• The appliance, when installed, must be electrically grounded in accordance with local codes or, in the
absence of local codes, with the National Electrical Code, ANSI / NFPA 70, in the US, or the Canadian
Electrical Code, CSA C22.1, in Canada.
• Caution:
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper
and dangerous operation. Verify proper operation after servicing.
FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THE DIAGRAMS IN THIS BOOKLET,
OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS APPLIANCE, MAY
RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY.
DO NOT OPERATE WITH THE GLASS FRONT REMOVED, CRACKED OR BROKEN. REPLACEMENT