180.OM.CL26.FS.IPI E v1.02
September 6, 2017
Page 14
Clarity 26 FS IPI
OPERATING INSTRUCTIONS cont.
BATTERY HOLDER / TRANSMITTER
The battery holder / transmitter consists of three elements:
Profl ame 2 Transmitter
Profl ame 2 Battery Holder
Profl ame 2 Integrated Fireplace Control (IFC)
TECHNICAL DATA:
Supply voltage
6.0V (four 1.5 V AA batteries)
Ambient temperature ratings
0 - 60 °C (32 - 140 °F)
FUNCTIONS:
The Profl ame 2 battery holder provides backup system
power during line power interruption through the
installed 4 AA batteries.
The Profl ame 2 battery holder connects directly to the
Profl ame 2 integrated fi replace control (IFC) board
through the 600.584.920 and 600.584.922 wire harness.
The Profl ame 2 battery holder has a three position slider
switch for system control. The slider switch can be set to one
of three positions:
1.
OFF position: With the slider in OFF position, the system
is “OFF”. No function can be selected by the transmitter.
No “beep” will be emitted from the Profl ame 2 IFC when a
command is sent by pressing any key on the transmitter
(for example the ON / OFF key).
2.
On position: With the slider in ON position, the burner
fl ame is “ON”. Only the other functions (Fan etc.) can be selected by the transmitter.
3.
Remote position: With the slide in Remote position, all the functions can be selected by the transmitter.
4.
Programming Button (PRG): When pushed allows a transmitter to be accepted for use by the system. See
“Initializing the System for the fi rst time” below.
PRG Key
3 Position Slider
ON / REMOTE / OFF
INITIALIZING THE TRANSMITTER / RECEIVER LINK SYSTEM FOR THE FIRST TIME
Install the 4 AA batteries into the Profl ame 2 Battery holder battery bay, it is located behind the magnetic pull
down fl ap that is directly below the fi rebox. Note the polarity of the battery and insert into the battery bay as
indicated on the cover (+/-). Place the 3 position slider switch in the “Remote” position. Press the “PRG”
button on the Receiver front cover. The Receiver will “beep” to indicate that it is ready to synchronize with
a Transmitter. Install 3 AAA type batteries in the Wall Mount Transmitter battery bay, located on the back of
the Transmitter and push the On button. The Receiver will “beep” to indicate the Transmitter’s command is
accepted and set to the particular code of that Transmitter. The system is now initialized.
LOW BATTERY POWER DETECTION
The life span of the Profl ame 2 IFC batteries depends on various factors: quality of the batteries used, the
number of ignitions of the appliance, the number of changes to the room thermostat set point etc. When the
Profl ame 2 IFC batteries are low, two (2) “beeps” will be emitted from the Profl ame 2 IFC every time it receives
a command from the Transmitter. This is an alert for a low battery condition for the Profl ame 2 IFC. When the
batteries are replaced one (1) “beep” will be emitted from the Profl ame 2 IFC when a command is sent by
pressing any key on the transmitter (for example the ON / OFF key), see “Initialization of The System”.