10.6 P.O. Check Valve
Item 6 (P002436) on Service Drawing 700-SD0010 is a duel pilot operated check valve.
When there is no outside pressure, i.e. if the rocker switch on the blade control joystick is not
pushed, the check valve prevents the cylinders from moving. When the rocker switch is
pushed the fluid will flow on one side of the cylinder and the pilot line will detect the fluid
pressure and open the hydraulic line on the other side of the cylinder to release the fluid from
other side of the cylinder, thus allowing the cylinder to move. When the rocker switch is
released, the cylinders again lock in place.
10.7 Oil
Cooler
Item 7 (P002373) on Service Drawing 700-SD0010 is a oil cooler with 30 psi bypass
valves. The oil from the gear pump, Item 2, is always going through the oil cooler while
the drive motor is on. The volume of oil passing through the oil cooler is dependant on
the drive motor rpm. The oil cooler is an air-over-oil cooler with the air being supplied
by a 12 volt DC fan. The 30 psi bypass valves will open if the pressure of the hydraulic
oil exceeds 30 psi. For example, if the temperature outside is extremely cold and the
hydraulic fluid has become thick, the pump will have a hard time pushing the oil through
the cooler, thus increasing the pressure. This increased pressure could cause damage to
the pump, therefore the oil cooler is bypassed at 30 psi and the pressure is reduced.