Revision B
Revised 5/20/2003 12:33 PM
37
Operating Instructions BMS-270LPII
Maintenance
7.5 Changing
Hydraulic Oil Filters Cont’d
7.5.2 Changing In-tank Suction Strainer and Suction Filters
1.
It is recommended that the equipment be placed in its “Maintenance Mode”
condition as outlined in Section 2.5.
2.
Let the multiscraper cool down.
3.
Disconnect any hydraulic system components/hoses that may obstruct access to
the hydraulic tank. Protect disconnected hoses from dirt and debris.
4.
Clean hydraulic tank access cover thoroughly with a clean, lint-free cloth. Ensure
that the tank is free of debris that may enter tank and contaminate the hydraulic
oil and damage the hydraulic system.
5.
Remove bolts on perimeter of the access cover and remove the cover.
6.
Replace filters.
7.
Re-attach hydraulic tank access cover, ensuring that all bolts are secure. Replace
gasket material on access cover if necessary.
DANGER: Be sure the oil has cooled down before changing the filters. The oil
temperature can be in excess of 200 deg F and will cause severe burns if touched.