MODEL BDC317P DUST COLLECTOR
OPERATING MANUAL
APRIL 2008
SECTION 9
FAULT DIAGNOSIS
43
Dust Collectors
Prior to any repair work on the machine or its drives, the
machine must be secured against unintentional activation. Put
the machine in its Safety off position. See section 2.6.
9.1 FAULT DIAGNOSIS – DUST COLLECTOR
Fault
Possible Cause
Remedy
The dust collector
does not start.
No power supply
Check if the outlet box
carries current.
Check the socket and the
cable of the dust collector
for damages.
Have the unit checked by
an electrician.
The R.P.M. of the
dust collector
increases.
Filter cartridges are clogged.
Suction hose is clogged.
Replace the filter
cartridges.
Check and clean the hose
assembly.
The dust collector
blows out dust.
Filter cartridges are damaged.
Replace the filter
cartridges.
The compressor
consumes too much
oil.
Too low oil viscosity.
Crankcase ventilation is
damaged.
Fill with the correct oil (see
section 7.4).
Clean or replace the
crankcase ventilation.