RackSwitch G8124 Installation Guide
BPP-00018-01, December 2009
Chapter 1: RackSwitch G8124 Description and Specifications
13
Transceivers are not included with the G8124 switch unit. The following transceivers are available
from Blade Network Technologies:
The RackSwitch G8124 accepts any SFP+ Direct Attach Cable that complies to the MSA
specification.
10/100/1000Base-T Ports
Two 10/100/1000BaseT ports (RJ-45) are located on the front panel. These management ports
support in-line management and Control Plane Stacking.
The following table describes the RJ-45 connector pin assignments.
Table 1
Recommended SFP+ Transceiver
Part number
Description
BN-CKM-SP-SR
SFP+ 10GBase-SR Short Range Optical Fiber Transceiver
BN-CKM-SP-LR
SFP+ 10GBase-LR Long Range Optical Fiber Transceiver
BN-CKM-S-T
SFP 1000BASE-T Copper Transceiver
BN-CKM-S-SX
SFP 1000BASE-T-SX Short Range Optical Transceiver
BN-CKM-S-LX
SFP 1000BASE-LX Long Range Fiber Transceiver
Table 2
RJ-45 Port pin assignments
Pin number
Signal
Description
1
BI DA+
Bi-directional data pair A positive
2
BI DA-
Bi-directional data pair A negative
3
BI DB+
Bi-directional data pair B positive
4
BI DC+
Bi-directional data pair C positive
5
BI DC-
Bi-directional data pair C negative
6
BI DB-
Bi-directional data pair B negative
7
BI DD+
Bi-directional data pair D positive
8
BI DD-
Bi-directional data pair D negative