3-15. Bandwidth Management
Function name:
Ingress Bandwidth Setting
Function description:
Ingress Bandwidth Setting function is used to set up the limit of Ingress
bandwidth for each port.
Fig. 3-62
Parameter description:
Port No.:
Choose the port that you would like this function to work on it. Valid
range of the port is 1~26.
Rate:
Set up the limit of Ingress bandwidth for the port you choose. Incoming
traffic will be discarded if the rate exceeds the value you set up in Data
Rate field. Pause frames are also generated if flow control is enabled.
The format of the packet limits to unicast, broadcast and multicast. Valid
value of Port 1~24 ranges from 66~102400, and Port 25~26 ranges from
66~1024000 with the minimum unit of 1. Default value of Port 1~24 is
102400 and Port 25~26 is 1024000.