3-12. Alarm Configuration
Function name:
Events Configuration
Function description:
The Trap Events Configuration function is used to enable the switch to send
out the trap information while pre-defined trap events occurred. The switch
offers 27 different trap events to users for switch management. The trap
information can be sent out in three ways, including email, mobile phone SMS
(short message system) and trap. The message will be sent while users tick
(
;
) the trap event individually on the web page shown as below.
Parameter description:
Trap: Cold Start, Warm Start, Link Down, Link Up, Authentication
Failure, User login, User logout
STP: STP Topology Changed, STP Disabled, STP Enabled
LACP: LACP Disabled, LACP Enabled, LACP Member Added,
LACP Port Failure
GVRP: GVRP Disabled, GVRP Enabled
VLAN: Port-based VLAN Enabled, Tag-based VLAN Enabled
Module Swap: Module Inserted, Module Removed, Dual Media Swapped,
Slot Inserted, Slot Removed
Power: Power Inserted, Power Removed, Power Normal,
Power Abnormal
Events Configuration