![Black Bruin B240 Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/black-bruin/b240/b240_product-manual_2764298033.webp)
In open loop hydraulic system the minimum pressure may be done with back
pressure. The back pressure is usually generated by a suitable check valve with
cracking pressure.
• CHARGE PRESSURE
In closed loop hydraulic system the charge pressure is usually used as the
minimum pressure.
In open loop hydraulic system the charge pressure may be done by a suitable
pressure reducing valve.
The required minimum pressure depends mainly on the flow rate in the working lines.
Recommended values for the minimum pressure are on the following figures:
WORKING LINE PRESSURE
[bar]
Figure 33. The minimum pressure at full
displacement (fluid viscosity 35 cSt).
[bar]
Flow rate [l/min]
WORKING LINE PRESSURE
[bar]
Figure 34. The minimum pressure at half
displacement (fluid viscosity 35 cSt).
[bar]
Flow rate [l/min]
Attention:
Too low pressure in the working lines causes the pistons to disconnect
from the cam ring when the motor is running. The effect of this is
clattering noise when the pistons reconnect.
Constant use with too low working line pressure may cause premature
wear or failure of the motor.
System Design
Product Manual
33