CHAPTER 7: Diagnostics and Troubleshooting
53
a. From the Command Port, enter:
>DI LOCComp <cr>
or
b. From the LCD/keypad, select from the
diagnostic menu as shown below:
Main Menu
Diagnostics
Local Composite
5. Verify that the TM indicator light goes on.
6. Type any data on the terminal connected in step
1, and verify that the data is echoed back as
typed.
7. Speak into the telephone. You should hear your
own voice echoed back.
8. Terminate the local composite loopback test as
described in
Section 7.2.
Verify that the TM
indicator light goes off.
Notes on FXO and E&M Interfaces
Figure 7-5 shows the voice/fax connections for FXO
and E&M type voice/fax interface modules; data
connections are not repeated. If your Multiserver
500 is fitted with an FXO type voice/fax interface
module, you must first dial the station number that
connects to the Multiserver 500 in order to perform
a voice test.
Similarly, if your Multiserver 500 is fitted with an
E&M type voice/fax interface module, you must
first dial the access code assigned to the Multiserver
500 in order to perform a voice test.