68
MINIMODEM USB
Command:
%%%AT<CR>
Remote
Configuration Escape Sequence
Values:
n/a
Description:
Initiates remote configuration mode
while online with remote modem. The
remote configuration escape character
(%) is defined in register S13.
5.3 S-Registers
Certain modem values, or parameters, are stored in
memory locations called S-registers. Use the
S
command
to read or to alter the contents of S-registers (see
previous section).
Register
Unit
Range
Default
Description
S0
1 ring
0, 1–255
1
Sets the number of rings until the
modem answers. ATS0=0
disables autoanswer completely.
S1
1 ring
0–255
0
Counts the rings that have
occurred.
S2
decimal
0–127
43 (+)
Sets ASCII code for the escape-
128–255
sequence character. Values
greater than 127 disable escape.
S3
decimal
0–127
13 (^M)
Sets the ASCII code for the
carriage-return character.
S4
decimal
0–127
10 (^J)
Sets the ASCII code for the line-
feed character.