MODULAR MODEM ELIMINATOR
3.5 Connecting the Cables
3.5.1 C
ONNECTOR
L
OCATION
Figure 3-6
identifies the connectors located on the rear panel of the Modular
Modem Eliminator. For information on connector wiring, refer to
Appendix A
.
Figure 3-6. Rear Panel.
3.5.2 D
ATA
C
ONNECTIONS
Refer to the installation plan and connect the data cables to the interface module
connectors J1 and J2.
3.5.3 P
OWER
C
ONNECTION
WARNING
When you plug in the Modem Eliminator, the protective earth terminals
of this instrument must be connected to the protective ground
conductor of the power cord. The plug must be inserted only in an outlet
provided with a protective earth (grounding) contact. The protective
action must not be negated by use of an extension cord without a
grounding conductor. Make sure that only fuses of the required rating,
as marked on the Modem Eliminator’s rear panel, are used for
replacement. Avoid using repaired fuses and short-circuiting fuse
holders. Whenever it is likely that the protection offered by fuses has
been impaired, the instrument must be made inoperative and be secured
against any unintended operation.
AC power should be supplied to the Modular Modem Eliminator through the
5-foot (1.5-m) standard power cable terminated by a standard 3-prong plug.
Connect the cable between the AC mains connector on the rear panel and
a standard grounded AC outlet.
AC Power
Connector
Connector J2
Connector J1
Fuse
Compartment