WAN Access High Speed Routers overview
17
WAN Access Routers Getting Started Guide
1 • General Information
Rear panel connectors and switches
On the rear panel from left to right are the following:
•
Power input connector
•
Ethernet connector
•
MDI-X switch
•
WAN port (V.35, X.21, T1/E1)
Power connector
AC universal power supply.
The WAN Access Router offers internal or external AC power supply options.
•
The internal power supply connects to an AC source via an IEC-320 connector (100–240 VAC, 200 mA,
50/60 Hz)
•
The external power supply connects to an external source pro5 VDC via a barrel-type connector
48 VDC power supply.
•
The DC power supply connects to a DC source via a terminal block
•
Rated voltage and current: 36–60 VDC, 400 mA
Ethernet port (outlined in green)
Shielded RJ-45 10Base-T/100Base-TX Ethernet port using pins 1, 2, 3, and 6. See MDI-X switch for hub or trans-
ceiver configuration.The following table defines conditions that occur when the MDI-X switch is in the out position.
Connect the equipment to a 36–60 VDC source that is electri-
cally isolated from the AC source. The 36–60 VDC source is to
be reliably connected to earth.
Pin No.
Signal
Direction
Signal
Name
1
Output
TX+
2
Output
TX-
3
Input
RX+
4
—
—
5
—
—
6
Input
RX-
7
—
—
8
—
—
CAUTION
Содержание LR120A
Страница 1: ...LR120A LR121A LR122A LR125A WAN Access Routers Getting Started Guide...
Страница 24: ...19 Chapter 2 Product Overview Chapter contents Introduction 20 Applications overview 21...
Страница 39: ...34 Chapter 4 Ethernet LAN Port Chapter contents Introduction 35 LAN connections 35 Ethernet Port 35...
Страница 115: ...110 Appendix B Cable recommendations Chapter contents Ethernet Cable 111 Adapter 111...
Страница 128: ......