ES10/ES26
Page 47/104
Document status: released
Operating Manual
rev. 01, 03.11.08
Settings
SBS Suppression
Change or show the SBS suppression mode
Channel Distance
Change or show the channel distance
OMI
Show OMI
totrms
, change the OMI
totrms
for AGC mode
RF Gain
Show RF gain, change RF Gain for manual gain
mode, related to the nominal gain for nominal OMI
and nominal RF-Input power. For RF gain 0 dB an
input level of 80 dBµV causes 5% OMI.
OMI nominal
Show nominal OMI
totrms
for AGC mode
SAT OMI
Show OMI
totrms
, change the OMI
totrms
for AGC mode
SAT RF Gain
Show SAT RF gain, change SAT RF Gain for manual
gain mode, related to the nominal gain for nominal
SAT OMI and nominal SAT RF-Input power.
SAT OMI nominal
Show nominal SAT OMI
totrms
for AGC mode
Laser Frequency
Change or show the lasers ITU optical frequency
(DWDM only)
Slope
Change or show RF slope for CATV input
SAT Slope
Change or show SAT RF slope for SAT input
AGC Mode
Change or show the AGC mode
SAT AGC Mode
Change or show the SAT AGC mode
Optical Output Power
Change or show optical output power
CSO Regulation Mode
Change or show the CSO regulation mode
I/O Port Mode
Change or show the I/O port mode
Output Port Mask
Change or show the output port mask
RF Input Alarmmode
Change or show RF input alarmmode
Parameters
RF Input
Shows RF total rms (root-mean-square) input power
of SAT-IF input signal
If the input power is out of range for the selected
OMI- or Gain-settings, an input warning will be
generated and the showed value may be not valid.
OMI
Shows the OMI total rms.
If the el. input power or the selected gain is out of
range for a measureable OMI value, an input
warning will be generated and the showed value
may be not valid.