The ES10XLa/ES26XLa is equipped with 4 data interfaces at the rear side:
•
RS232 for a local set-up of the NMS Interface,
•
RS485 (master) for polling other BKtel equipment like EDFAs or optical switches and
translating this information to the Ethernet interface (HTTP and SNMP),
•
Ethernet 10/100 Base-T supporting SNMP and Webserver (HTTP) protocols for
interfacing to a EMS or NMS
•
General purpose I/O interface
The ES10L/XLb is equipped with two RS485 (slave) interfaces for interfacing to an EMS or NMS.
Additionally, there are two output ports available for simple alarm or warning messaging.
Plug in power supply/fan modules for different input voltages are available for 100 ... 240 VAC,
36 ... 60 VDC and 24 VDC. Each module can be simply removed during operation without
disturbing the operation of the transmitter by removing 2 screws.