Operations
36
Transient Resistance Level
A/B transient resistance level can be set on front panel or by remote operation. The load can continuously toggle between
the two levels when transient operation is turned on.
4.1.4 Constant Power (CP) Mode
In CP mode, the electronic load will consume a constant power. When input voltage increases, the input current will
dexrease, while power (P = V * I) will remain the same.
Figure 4.5
Constant Power Mode
CP Ranges
When working in CW mode, you can Press the the
key to enter the RANGE menu. Two overlapping ranges can
be selected: LOW RANGE or HIGH RANGE. Power can be edited in either of the two ranges.
Low range will supply higher accuracy and better resolution when you set lower power. If any value you set is outside the
maximum value of the LOW RANGE, you should select HIGH RANGE. If the electronic load is in remote control mode,
you can use the POW:RANG command to switch power range.
CP Vmax/Vmin Limits
These parameters refer to the voltage high and low limit for the automatic test mode. During automatic test mode, the
device under test (DUT) must be operating within the configured values for the test to PASS upon completion. If the
DUT operates outside the configured values, the test will FAIL upon completion.
Note:
These parameters are used for
ONLY
.
Immediate Power Level
Set the power level via the front panel. If the load is in CW mode, the new power level setting immediately changes the
input. If the load is not in CW mode, the power level setting will be saved for use until mode is switched to CW mode.
Transient Power Level
A/B transient power level can be set via the front panel or by remote operation. The electronic load can continuously
toggle between the two levels when transient operation is turned on.