Load Connection
30
3.4 External ON/OFF Control Connection
ON/OFF IN (pin 3 of rear 8-pin Control Connector) is used to toggle the multi-channel electronic load inputs ON or
OFF. When ON/OFF IN pin receives a TTL level pulse (>10us), the ON/OFF state of the load will toggle. SYNC ON
SET function can be set to ON for multiple channels to toggle more than one channel at a time.
ON/OFF OUT (pin 4 of rear 8-pin Control Connector) indicates ON/OFF state of the multi-channel electronic load. If
SYNC ON SET function of any specific channel is set to ON and the channel’s input state is ON, pin 4 outputs a low
TTL level signal. If the input state is off, pin 4 outputs a high TTL level signal.
3.5 Mainframe Extension Connection
Figure 3.5
Mainframe Extension Connection
The
Extended Mainframe
interface is used to connect the mainframe extension to expand the number of channels. Up
to 16 total channels can be supported when mainframe is connected to the mainframe extension.
Procedure:
1. Use expansion cable to connect the mainframe extension interface between the mainframe and mainframe extension.
2. Press
+
to enter System menu.
3. Use the
keys to navigate through menu.
4. Select
Expand Module
and choose ON to enable expand function.
5. Press Enter to confirm.