Operations
59
25. Repeat steps 17 through 20 and set the rest of the steps’ load on/off time.
26. Set condition for when to stop testing.
– COMPLETE means to stop test when all steps are completed.
– FAILURE means to stop test when testing fails.
– Press the
keys to select condition and press the
to confirm.
27. Program chain is used when you need to link to the next file to be tested.
– For example, to link to group 2, press the 2.
– If no other file needs to be linked, input
and then press the
key to confirm.
28. Save the edited files into the EEPROM. Up to 10 program files can be saved.
– For instance, press the 1 to save the edited file to program file 1 and then press the
to confirm.
29. Press the
key to exit menu.
4.15.2 Recall Test Files
The following is a procedure on how to recall edited test files from the EEPROM:
1. Press
+
to enter the
Program
menu.
2. Press
key to select
Recall Prog
and press
.
3. Input the saved program number and press
to recall the saved testing file.
4. To run the program, press
key to select
Run Program
and press
.
5. Press
key to start automatic testing.
– To pause, press
key and then press
key to continue.