DB-200-6
41
4.7
Dimensions and refrigerant connections:
standard design
Versions for 4 passes and 2 passes are only listed sep-
arately, if the dimensions are different.
Detailed dimensions of the reversing covers see see
chapter Dimensions of reversing covers and coolant
connections, page 38.
K033N(P), K033H(P), K073H(P) and K123H(P)
A
A1
H
I
X
R1
Ø9
Y
R
Ø
E
U
F
6
2
7
1
W
V
B1
G
C
E1
L
S
6
B
Z
T
D
12
11
Model
A
A1
B
B1
C
C1
D
E
E1
F
G
H
I
K033N(P)
606
517
152
130
184
–
108
50
154
50
110
400
58
K033H(P)
606
517
152
130
184
–
108
50
154
50
110
400
58
K073H(P)
606
517
152
130
184
–
108
50
154
50
110
400
58
K123H(P)
856
767
152
130
172
–
108
60
154
60
110
400
188
Model
L
R
R1
S
T
U
U1
U2
V
W
X
Y
Z
K033N(P)
–
60
45
62
–
–
–
–
212
250
47
6
87
K033H(P)
125
60
45
62
132
236
–
–
212
250
47
6
87
K073H(P)
125
60
45
62
132
236
–
–
212
250
47
6
87
K123H(P)
125
60
50
62
262
295
–
–
275
320
47
6
87
Model
Refrigerant connections, positions 1 and 2
bushing
thread/flange
inlet Ø
outlet Ø
inlet
outlet
mm
inch
mm
inch
K033N(P)
12
1/2
10
3/8
1-14 UNS
3/4-16 UNF
K033H(P)
12
1/2
10
3/8
1-14 UNS
3/4-16 UNF
K073H(P)
12
1/2
10
3/8
1-14 UNS
3/4-16 UNF
K123H(P)
16
5/8
12
1/2
1-14 UNS
1-14 UNS
Tab. 4: No additional refrigerant outlet available.