background image

Bitstorm Inc. 

 

 

Bad Boy Xtreme 

www.bitstorm.com 

Chapter 1 - Bench Test 

 

Check off items as completed.  

 

Step 1 

 

 

Remove the protective cap from Antenna connector and attach to Xtreme. 
Finger tight is adequate. 

Do not over tighten.

 

 

Step 2 

(Do this step if an optional Unleashed or Unleashed HP 

 

 

 is included as part of your system)

 

DUO comes pre-configured with Port 2 PoE disabled. If Unleashed is included, 
power injection must be enabled on Port 2. To enable Port 2 power:

 

 

Open the case by removing the four screws from the back of the Power In-
jector DUO.

 

 

Move 

BOTH

 jumpers 

JP1

 and 

JP2

 to position 

1-2

 

to enable power on Port 2. 

Jumpers come factory configured to positions 

2-3

 which disables

 

power on 

Port 2.      

NOTE: Both jumpers must be positioned identically.

 

 

Close case and refasten four screws on back.  

 

 

 
Step 3 

 

Connect power to DUO using either AC or DC.

 

 

Verify  that  the  Green  LED  is  lit  on  Port  1  (and  Port  2  if  enabled  in  Step  2).  

Note: If Yellow Power Fault LEDs illuminate, it indicates a reverse polarity 
connection.  In  this  condition,  circuit  protection will prevent  power  being 
applied to either Port 1 or Port 2. 

AC 

Plug in an AC Adapter (included with M-POE-DUO-S15.5) with proper 
rating and insert barrel plug into DUO`s power connector. 

DC

 

Connect the Power Cable (included) to an appropriate power source.  
Connect  the  red  (or  white  striped)  wire  to  po)  and  the  solid 
black wire to negative(-). Insert barrel plug into DUO. 

Port 2 Power Enabled 

Port 2 Power Disabled 

Содержание Bad Boy Xtreme BB-XABC75

Страница 1: ...nstallation and Operation Guide Revision 1 6a BB XARC75 Rail Flat Surface BB XASC75 1 14 Adapter BB XABC75 Backstay BB XAPC75 Pole Getting YOU on the web Models covered Hi Power Wi Fi Antenna Rail mou...

Страница 2: ...rrectly in your Junction Box Your warranty may be affected Note Failure to bench test will indicate your acceptance that your system was completely and fully operational prior to installation Declarat...

Страница 3: ...ration Guide Copyright Trademarks Specifications are subject to change without notice Other brands and product names are trade marks or registered trademarks of their respective holders No part of the...

Страница 4: ...me factory configured to positions 2 3 which disables power on Port 2 NOTE Both jumpers must be positioned identically Close case and refasten four screws on back Step 3 Connect power to DUO using eit...

Страница 5: ...devices to Port 1 Step 5 Plug patch cable included in kit into Port 2 of the DUO Connect other end to computer networking devices or optional Unleashed Observe that the green LAN LED illuminates on X...

Страница 6: ...le needed to get from the mounting location to the deck transit location the place where the cable will go through the deck and then to a convenient place for splicing below deck Ensure that suffi cie...

Страница 7: ...re is no need to strip the insulation from the individual wires Refer to photo Connect the wires to the spade terminals using the tool s metal tip Lay the wire onto the spade and push down with the to...

Страница 8: ...em to become fully operational Without BAD BOY Unleashed option installed Turn off Wi Fi devices in your computer to prevent multiple simultane ous Wi Fi connections Refer to your computer manual for...

Страница 9: ...e hotspots By selecting a hotspot from the list any previously entered Key will be retrieved Any changes made to the Key value will be remembered A Forget Hotspot button allows a remembered Key to be...

Страница 10: ...onnecting to the hotspot simply try to open a web page and see whether an additional authentication is presented by the hotspot That page may include a request for payment for internet access Note On...

Страница 11: ...IC RS210 Controlled via Web Browser no software installation needed Radome Size 16 x 6 41cm x 1 6cm Outdoor Cable Type 75 feet 23m black UV protected PVC jacket Junction Box Included with punchdown t...

Страница 12: ...m x 2 8cm Remote Reset No Yes A reset allows settings to be restored to a known state For example this can be useful to restore username or password to default values To perform a Reset operation do t...

Страница 13: ...hen scroll the list select Internet Protocol Version 4 TCP IPv4 and then click Properties Ensure that the Obtain an IP address automatically and Obtain DNS server address automatically radio buttons a...

Страница 14: ...ddress entered Ensure you type xtreme wifi no e Unable To Connect To Xtreme s Management Tool 1 No power Refer to LAN LED Not Illuminating 2 Cable not connected Refer to LAN LED Not Illuminating 3 Can...

Страница 15: ...way shape or form c has been damaged due to errors or defects in customer provided cabling d has been subjected to abnormal physical or electrical stress including lightening strike misuse negligence...

Страница 16: ...o the cockpit dragging a cable along You wish that you could cut that tether that umbilical cord that ball and chain You want to be Unleashed Ideally suited where cabling to computers is undesireable...

Отзывы: