During the periodic polling actions, the Configurator receives three
parameters from gauge, i.e., temperature, frequency, and fuel
level. They are visualized in the respective cells and are not
available for editing.
6
First step for setting up the FG. Specify the FG network address in
the appropriate cell and apply the changes using the button
to the right of the cell.
7
Second step for setting up the FG. Specify the level corresponding
to the empty tank.
8
We recommended that you set a low level of data filtering before
starting the gaging procedure.
9
Within the process of gaging, the data are constantly changing.
Use parameters to stabilize the readings for convenience in
processing these data. Specify the number of positions to assess
stabilization (default value is 10) and the stabilization deviation
(default value is 5). If in the last ten positions the difference
between the minimum and maximum values is not more than 5,
the readings will be considered stabilized.
10
Use the properly button to restore the factory settings of the
gauge.
During the gaging, switch to the Gauge gaging tab. In addition, the
configurator window will be as shown below:
11
Changing of fuel gauge readings in real time mode can be
conveniently monitored using the time schedule of temperature
and level. Remove data of the graph using the button