17
The 1-byte parameter type filter with ID = 0209 was entered to
select the used filter type; default value
When setparam value is setparam 0209 0, the Butterworth filter is
used,
For properly operation of the filter, it is desirable to set the
following data:
Kalman filter is used at the value of parameter.
setparam 0209 1
;
Example of standard setting via SMS:
setparam 0950 1000000;
setparam 0951 2000000;
setparam 0952 1000000;
setparam 0953 20000000;
setparam 0954 400000000;
Value of the last valid level of fuel
setparam 0819 1;
Timeout of movement start according to the accelerometer
setparam 0284 50;
Timeout of movement stop according to the accelerometer
setparam 0285 200;
2.
Transfer to the database server without fuel level filtering:
Not
filtered data of fuel gauge
Table. Unfiltered data of fuel gauge
1
network
address
2
network
address
5
network
address
6
network
address
Parameter
Value
Parameter
Description
ID 112
ID 113
ID 131
ID 132
ID at transfer
setparam
0690
setparam
0700
setparam
0870
setparam
0880
1
To activate the
parameter
setparam
0691
setparam
0701
setparam
0871
setparam
0881
0
Priority
setparam
0692
setparam
0702
setparam
0872
setparam
0882
0
Upper limit off
setparam
0693
setparam
0703
setparam
0873
setparam
0883
0
Lower limit off
setparam
0694
setparam
0704
setparam
0874
setparam
0884
3
Monitoring mode
setparam
0695
setparam
0705
setparam
0875
setparam
0885
5
Constant
of averaging