INSTALLATION, OPERATION AND MAINTENANCE MANUAL
BiSolid Comfort OM-BSCV00/08/2012/EN
13
Danger
When installing the elements for safety and control please do not forget that all
installation works must comply with the safety labor principles. If thermo-
regulation valve or other safety element replacement is necessary, please use
the recommended devices. In case of using any other type of devices you
should ask the supplier first. The thermo-regulating valve must be checked by
authorized specialist once per year.
The change of the flap position controls the burning intensity and by that the boiler heating
output (when operating with wood logs). The thermo-regulating valve is connected to the
control flap by a chain. The chain is connected to the flap in such way that the thermo-
regulating valve tensioning can be adjusted (Figure 5).
Figure 5. Control flap.
Warning
When the boiler operates with wood pellets the chain must be disconnected
from the flap. The necessary air for firing is supplied by the pellet burner fresh
air fan.
Danger
Keep any objects away from the regulating flap and from the grooves providing
primary air intake.
The hot water temperature can be measured by thermometer (Figure 6), which is situated on
the front boiler panel, over the fuel feeding door.